Pickl, KE; Magnes, C; Bodenlenz, M; Pieber, TR; Sinner, FM.
Rapid online-SPE-MS/MS method for ketoprofen determination in dermal interstitial fluid samples from rats obtained by microdialysis or open-flow microperfusion.
J Chromatogr B Analyt Technol Biomed Life Sci. 2007; 850(1-2):432-439 Doi: 10.1016/j.jchromb.2006.12.026
Web of Science PubMed FullText FullText_MUG Google Scholar

 

Führende Autor*innen der Med Uni Graz
Sinner Frank Michael
Co-Autor*innen der Med Uni Graz
Pieber Thomas
Weiss Manfred
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Pharmacokinetic studies of topical ketoprofen formulations using continuous sampling techniques such as microdialysis (MD) or open-flow microperfusion (OFM) require sensitive assays due to small sample volumes. A simple and easy online-SPE-MS/MS method for ketoprofen analysis was developed for both MD and OFM samples obtained from rat dermal tissue. The quantification range is 25-5000 ng/ml with a limit of detection of 3 ng/ml using only 10 microl sample volume. The method is characterized by a simple setup using a short polymeric SPE column (OASIS HLB) for desalting with 1.5 min run times in combination with a sensitive MS detection in negative ESI MRM mode. An easy sample workup procedure was used which enables high throughput analysis of a large number of samples for pharmacokinetic studies. In addition, a commercial available (fenoprofen) as well as an isotopically labelled (deuterated ketoprofen) standard were investigated as potential internal standards. The method was validated according to FDA guidelines for bioanalytical validation in terms of accuracy, intra-batch and inter-batch precision, linearity, matrix effect, recovery and stability for both internal standards. Accuracies were 98-113% (fenoprofen) and 95-108% (deuterated ketoprofen), intra-batch precision was 2-3% R.S.D. (fenoprofen) and 2-6% R.S.D. (deuterated ketoprofen), and inter-batch precision was 2-6% R.S.D. (fenoprofen) and 3-6% R.S.D. (deuterated ketoprofen) over the entire quantification range. The presented method was applied to dermal interstitial fluid samples obtained in a topical administration study of ketoprofen in rats.
Find related publications in this database (using NLM MeSH Indexing)
Animals -
Anti-Inflammatory Agents, Non-Steroidal - analysis
Extracellular Fluid - chemistry
Ketoprofen - analysis
Microdialysis -
Rats -
Reference Standards -
Reproducibility of Results -
Sensitivity and Specificity -
Skin - chemistry
Tandem Mass Spectrometry - methods

Find related publications in this database (Keywords)
ketoprofen
interstitial fluids
microdialysis
open-flow microperfusion