Sidhu, BS; Lee, AWC; Gould, J; Porter, B; Sieniewicz, B; Elliott, MK; Mehta, VS; Wijesuriya, N; Amadou, AA; Plank, G; Haberland, U; Rajani, R; Rinaldi, CA; Niederer, SA.
Guided implantation of a leadless left ventricular endocardial electrode and acoustic transmitter using computed tomography anatomy, dynamic perfusion and mechanics, and predicted activation pattern.
Heart Rhythm. 2023; 20(11):1481-1488 Doi: 10.1016/j.hrthm.2023.07.007 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Co-authors Med Uni Graz
Plank Gernot
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
BACKGROUND: The WiSE-CRT System (EBR systems, Sunnyvale, CA) permits leadless left ventricular pacing. Currently, no intraprocedural guidance is used to target optimal electrode placement while simultaneously guiding acoustic transmitter placement in close proximity to the electrode to ensure adequate power delivery. OBJECTIVE: The purpose of this study was to assess the use of computed tomography (CT) anatomy, dynamic perfusion and mechanics, and predicted activation pattern to identify both the optimal electrode and transmitter locations. METHODS: A novel CT protocol was developed using preprocedural imaging and simulation to identify target segments (TSs) for electrode implantation, with late electrical and mechanical activation, with ≥5 mm wall thickness without perfusion defects. Modeling of the acoustic intensity from different transmitter implantation sites to the TSs was used to identify the optimal transmitter location. During implantation, TSs were overlaid on fluoroscopy to guide optimal electrode location that were evaluated by acute hemodynamic response (AHR) by measuring the maximal rate of left ventricular pressure rise with biventricular pacing. RESULTS: Ten patients underwent the implantation procedure. The transmitter could be implanted within the recommended site on the basis of preprocedural analysis in all patients. CT identified a mean of 4.8 ± 3.5 segments per patient with wall thickness < 5 mm. During electrode implantation, biventricular pacing within TSs resulted in a significant improvement in AHR vs non-TSs (25.5% ± 8.8% vs 12.9% ± 8.6%; P < .001). Pacing in CT-identified scar resulted in either failure to capture or minimal AHR improvement. The electrode was targeted to the TSs in all patients and was implanted in the TSs in 80%. CONCLUSION: Preprocedural imaging and modeling data with intraprocedural guidance can successfully guide WiSE-CRT electrode and transmitter implantation to allow optimal AHR and adequate power delivery.
Find related publications in this database (using NLM MeSH Indexing)
Humans - administration & dosage
Cardiac Resynchronization Therapy Devices - administration & dosage
Heart Failure - therapy
Cardiac Resynchronization Therapy - methods
Electrodes - administration & dosage
Tomography, X-Ray Computed - administration & dosage
Perfusion - administration & dosage
Treatment Outcome - administration & dosage
Heart Ventricles - diagnostic imaging

Find related publications in this database (Keywords)
Cardiac resynchronization therapy
Endocardial pacing
Guiding endocardial pacing
Hemodynamic assessment
WiSE-CRT