Rodero, C; Strocchi, M; Marciniak, M; Longobardi, S; Whitaker, J; O'Neill, MD; Gillette, K; Augustin, C; Plank, G; Vigmond, EJ; Lamata, P; Niederer, SA.
Linking statistical shape models and simulated function in the healthy adult human heart.
PLoS Comput Biol. 2021; 17(4):e1008851 Doi: 10.1371/journal.pcbi.1008851 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Co-authors Med Uni Graz
Augustin Christoph
Gillette Karli
Plank Gernot
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Cardiac anatomy plays a crucial role in determining cardiac function. However, there is a poor understanding of how specific and localised anatomical changes affect different cardiac functional outputs. In this work, we test the hypothesis that in a statistical shape model (SSM), the modes that are most relevant for describing anatomy are also most important for determining the output of cardiac electromechanics simulations. We made patient-specific four-chamber heart meshes (n = 20) from cardiac CT images in asymptomatic subjects and created a SSM from 19 cases. Nine modes captured 90% of the anatomical variation in the SSM. Functional simulation outputs correlated best with modes 2, 3 and 9 on average (R = 0.49 ± 0.17, 0.37 ± 0.23 and 0.34 ± 0.17 respectively). We performed a global sensitivity analysis to identify the different modes responsible for different simulated electrical and mechanical measures of cardiac function. Modes 2 and 9 were the most important for determining simulated left ventricular mechanics and pressure-derived phenotypes. Mode 2 explained 28.56 ± 16.48% and 25.5 ± 20.85, and mode 9 explained 12.1 ± 8.74% and 13.54 ± 16.91% of the variances of mechanics and pressure-derived phenotypes, respectively. Electrophysiological biomarkers were explained by the interaction of 3 ± 1 modes. In the healthy adult human heart, shape modes that explain large portions of anatomical variance do not explain equivalent levels of electromechanical functional variation. As a result, in cardiac models, representing patient anatomy using a limited number of modes of anatomical variation can cause a loss in accuracy of simulated electromechanical function.
Find related publications in this database (using NLM MeSH Indexing)
Adult - administration & dosage
Healthy Volunteers - administration & dosage
Heart - anatomy & histology, physiology
Humans - administration & dosage
Models, Cardiovascular - administration & dosage
Tomography, X-Ray Computed - administration & dosage

© Med Uni GrazImprint