Vigmond, EJ; Neic, A; Blauer, J; Swenson, D; Plank, G.
How Electrode Position Affects Selective His Bundle Capture: A Modelling Study.
IEEE Trans Biomed Eng. 2021; 68(11):3410-3416 Doi: 10.1109/TBME.2021.3072334 [OPEN ACCESS]
Web of Science PubMed FullText FullText_MUG

 

Co-authors Med Uni Graz
Neic Aurel-Vasile
Plank Gernot
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
In certain cardiac conduction system pathologies, like bundle branch block, block may be proximal, allowing for electrical stimulation of the more distal His bundle to most effectively restore activation. While selective stimulation of the His bundle is sought, surrounding myocardium may also be excited, resulting in nonselective pacing. The myocardium and His bundle have distinct capture thresholds, but the factors affecting whether His bundle pacing is selective or nonselective remain unelucidated. OBJECTIVE: We investigated the properties which affect the capture thresholds in order to improve selective pacing. METHODS: We performed biophysically detailed, computer simulations of a His fibre running through a septal wedge preparation to compute capture thresholds under various configurations of electrode polarity and orientation. RESULTS: The myocardial capture threshold was close to that of the His bundle. The His fibre needed to intersect with the electrode tip to favor its activation. Inserting the electrode fully within the septum increased the myocardial capture threshold. Reversing polarity, to rely on anode break excitation, also increased the ease of selective pacing. CONCLUSION: Model results were consistent with clinical observations. For selective pacing, the tip needs to be in contact with the His fibre and anodal stimulation is preferable. SIGNIFICANCE: This study provides insight into helping establish electrode and stimulation parameters for selective His bundle pacing in patients.
Find related publications in this database (using NLM MeSH Indexing)
Bundle of His - administration & dosage
Bundle-Branch Block - therapy
Cardiac Pacing, Artificial - administration & dosage
Electrocardiography - administration & dosage
Electrodes - administration & dosage
Heart Rate - administration & dosage
Humans - administration & dosage

Find related publications in this database (Keywords)
Electrodes
Myocardium
Azimuth
Conductivity
Surface impedance
Extracellular
Current density
His bundle pacing
cardiac electrophysiology
electrical stimulation
computer modelling
© Med Uni GrazImprint