Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Cantinotti, M; Marchese, P; Scalese, M; Franchi, E; Assanta, N; Koestenberger, M; Van, den, Eynde, J; Kutty, S; Giordano, R.
Normal Values and Patterns of Normality and Physiological Variability of Mitral and Tricuspid Inflow Pulsed Doppler in Healthy Children.
Healthcare (Basel). 2022; 10(2): Doi: 10.3390/healthcare10020355 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Co-Autor*innen der Med Uni Graz
Koestenberger Martin
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
BACKGROUND: While mitral (MV) and tricuspid valve (TV) pulsed Doppler velocities and derived gradients are commonly evaluated, data on normal pediatric values are limited. This study aimed to evaluate the normal values and physiological variability for MV and TV Doppler velocities and derived gradients in a large cohort of prospectively enrolled healthy children. METHODS: The echocardiographic measurements included pulsed Doppler MV and TV E and A velocities, E deceleration times (EDT), maximal and mean gradients, and velocity time integral (VTI). RESULTS: A total of 544 healthy subjects (median age 6.4 years, range 1 day-17.68 years) were included. MV and TV E velocity, E/A ratio, and E and A wave duration increased, while A velocity decreased with age (p < 0.001). Along with an increase in VTI, there occurred a progressive increase in maximum velocity and gradients and a decrease in mean velocities and gradients. E/A inversions were common, especially at the TV in neonates and infants. For MV, inversion in either one, two, or three consecutive beats occurred in 51.9% of neonates and 18.3% of infants, while it was rare at older ages (all p < 0.001). For TV, inversions in three consecutive beats occurred in 71.4% of neonates, while inversions in only one or two beats were more common in infants (27.3%). For TV, inversion in one or more beats, however, was not infrequent at all ages. CONCLUSIONS: We report normal values and patterns of normality and physiological variability for MV and TV inflow Doppler from a large population of healthy children.

Find related publications in this database (Keywords)
diastolic function
doppler
heart defects
congenital
echocardiography
right ventricle
ventricular dysfunction
© Med Uni Graz Impressum