Schmid, J; Nagy, E; Kaufmann-Bühler, AK; Steiner, J; Janisch, M; Janek, E; Reiter, C; Eibisberger, M; Softic, N; Guss, H; Fuchsjäger, M; Adelsmayr, G.
Diagnosing Pulmonary Embolism With Computed Tomography Pulmonary Angiography: Diagnostic Accuracy of a Reduced Scan Range.
J Thorac Imaging. 2022; 37(5):323-330 Doi: 10.1097/RTI.0000000000000664 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Schmid Johannes
Co-Autor*innen der Med Uni Graz
Adelsmayr Gabriel
Eibisberger Martin
Fuchsjäger Michael
Janek Elmar
Janisch Michael August Johann
Kaufmann-Bühler Ann-Katrin
Nagy Eszter
Reiter Clemens
Softic Nina
Steiner Jakob
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
PURPOSE: Computed tomography pulmonary angiography (CT-PA) is frequently used in the diagnostic workup of pulmonary embolism (PE), even in highly radiosensitive patient populations. This study aims to assess CT-PA with reduced z -axis coverage (compared with a standard scan range covering the entire lung) for its sensitivity for detecting PE and its potential to reduce the radiation dose. MATERIALS AND METHODS: We retrospectively analyzed 602 consecutive CT-PA scans with definite or possible PE reported. A reduced scan range was defined based on the topogram, where the cranial slice was set at the top of the aortic arch and the caudal slice at the top of the lower hemidiaphragm. Locations of emboli in relation to the reduced scan range were recorded. RESULTS: We included 513 CT-PA scans with definite acute PE in statistical analysis. Patients' median age was 66 (52 to 77) years, 46% were female. Median dose length product was 270.8 (111.3 to 503.9) mGy*cm. Comparing the original and reduced scan ranges, the mean scan length was significantly reduced by 48.0±8.6% (26.8±3.0 vs. 13.9±2.6 cm, P <0.001). Single emboli outside the reduced range in addition to emboli within were found in 15 scans (2.9%), while only 1 scan (0.2%) had an embolus outside the reduced range and none within it. The resulting sensitivity of CT-PA with reduced scan range was 99.81% (95% confidence interval: 98.74%-99.99%) for detecting any PE. CONCLUSION: A reduced scan length in CT-PA, as defined above, would substantially decrease radiation dose while maintaining diagnostic accuracy for detecting PE.
Find related publications in this database (using NLM MeSH Indexing)
Aged - administration & dosage
Angiography - methods
Computed Tomography Angiography - administration & dosage
Female - administration & dosage
Humans - administration & dosage
Lung - administration & dosage
Male - administration & dosage
Pulmonary Embolism - diagnostic imaging
Radiation Dosage - administration & dosage
Retrospective Studies - administration & dosage
Tomography, X-Ray Computed - methods

Find related publications in this database (Keywords)
pulmonary embolism
computed tomography
pulmonary angiography
radiation dose
sensitivity