Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Campos, FO; Bhagirath, P; Monaci, S; Chen, Z; Whitaker, J; Plank, G; Rinaldi, CA; Bishop, MJ.
Reconstructed scar morphology in patient-specific computational heart models has limited impact on the identification of ablation targets through in-silico pace mapping.
Comput Biol Med. 2025; 191:110229 Doi: 10.1016/j.compbiomed.2025.110229
PubMed FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Campos Fernando Otaviano
Co-Autor*innen der Med Uni Graz
Plank Gernot
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
BACKGROUND: Patient-specific computational modeling for guiding ventricular tachycardia (VT) ablation often requires precise scar reconstruction to simulate reentrant circuits. However, this can be limited by the quality of scar imaging data. In-silico pace mapping, which simulates pacing rather than VT circuits, may offer a more robust approach to identifying ablation targets. OBJECTIVE: To investigate how the anatomical detail of scar reconstructions within computational image-based heart models influences the ability of in-silico pace mapping to identify VT origins. METHODS: VT was simulated in 15 patient-specific models reconstructed from high-resolution contrast-enhanced cardiac magnetic resonance (CMR). The obtained scar anatomy was then altered to mimic heart models constructed based on low-quality imaging and no-scar data. The ECG of each simulated VT was taken as input for the in-silico pace mapping approach, which involved pacing the heart at 1000 random sites surrounding the infarct. Correlations between the VT and paced ECGs were used to compute pace maps. The distance (d) between visually identified exit sites (ground truth) and pacing locations with the strongest correlation was used to assess accuracy of our in-silico approach. RESULTS: The performance of in-silico pace mapping was highest in high-resolution scar models (d = 7.3 ± 7.0 mm), but low-resolution and no-scar models still adequately located exit sites (d = 8.5 ± 6.5 mm and 13.3 ± 12.2 mm, respectively). CONCLUSION: In-silico pace mapping provides a reliable method for identifying VT ablation targets, showing relative insensitivity to scar reconstruction quality. This advantage may support its clinical translation over methods requiring explicit VT simulation.
Find related publications in this database (using NLM MeSH Indexing)
Humans - administration & dosage
Cicatrix - diagnostic imaging, physiopathology, pathology
Tachycardia, Ventricular - physiopathology, diagnostic imaging, surgery
Models, Cardiovascular - administration & dosage
Electrocardiography - administration & dosage
Catheter Ablation - administration & dosage
Male - administration & dosage
Computer Simulation - administration & dosage
Magnetic Resonance Imaging - administration & dosage
Patient-Specific Modeling - administration & dosage
Female - administration & dosage

© Med Uni Graz Impressum