Schmölzer, GM; Hooper, SB; Crossley, KJ; Allison, BJ; Morley, CJ; Davis, PG.
Assessment of gas flow waves for endotracheal tube placement in an ovine model of neonatal resuscitation.
Resuscitation. 2010; 81(6): 737-741. Doi: 10.1016/j.resuscitation.2010.02.018
Web of Science PubMed FullText FullText_MUG

 

Leading authors Med Uni Graz
Schmölzer Georg
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Aim: Clinical assessment and end-tidal CO2 (ETCO2) detectors are routinely used to verify correct endotracheal tube (ETT) placement. However, ETCO2 detectors may mislead clinicians by failing to correctly identify placement of an Elf under a variety of circumstances. A flow sensor measures and displays gas flow in and out of an ETT. We compared endotracheal flow sensor recordings with a colorimetric CO2-detector (Pedi-Cap (R)) to detect endotracheal intubation in a preterm sheep model of neonatal resuscitation. Methods: Six preterm lambs were intubated and ventilated immediately after delivery. At 5 min the oesophagus was also intubated with a similar tube. The endotracheal tube and oesophageal tubes were attached to a Pedi-Cap (R) and flow sensor in random order. Two observers, blinded to the positions of the tubes, used a ETCO2 detector and the flow sensor recording to determine whether the tube was in the trachea or oesophagus. The experiment was repeated 10 times for each animal. In the last three animals (30 recordings) the number of inflations required to correctly identify the tube placement was noted. Results: The Pedi-Cap (R) and the flow sensor correctly identified tube placement in all studies. Thus, the sensitivity, specificity, and positive and negative predictive values of both devices were 100%. At least three, and up to 10, inflations were required to identify tube location with the Pedi-Cap (R) compared to one or two inflations with the flow sensor. Conclusion: A flow sensor correctly identifies tube placement within the first two inflations. The Pedi-Cap (R) required more inflations to correctly identify tube placement. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Find related publications in this database (using NLM MeSH Indexing)
Animals -
Animals, Newborn -
Carbon Dioxide - analysis
Colorimetry - instrumentation
Esophagus -
Gases -
Gestational Age -
Intubation, Intratracheal -
Positive-Pressure Respiration -
Pulmonary Ventilation -
Respiration -
Sheep -
Tidal Volume -
Trachea -

Find related publications in this database (Keywords)
Delivery room
Infant
Respiratory function monitor
Neonatal resuscitation
Intubation
Colorimetric carbon dioxide detector
© Med Uni GrazImprint