Roetman, B; Schildhauer, TA; Muhr, G.
Pelvic stabilization in cases of septic instability. Triangular osteosynthesis in case of infection related vertical pelvic ring instability
Unfallchirurg. 2006; 109(5):422-424 Doi: 10.1007/s00113-006-1112-7 (- Case Report)
Web of Science PubMed FullText FullText_MUG

 

Co-Autor*innen der Med Uni Graz
Schildhauer Thomas Armin
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
The combination of transiliac screws and lumbopelvic distraction osteosynthesis is usually an appropriate procedure to treat vertical pelvic ring instabilities under the condition of full weight bearing. In this case, due to the extent of septic destruction of the dorsal portion of the iliac bone, the common triangular fixation method using conventional pedicle screws was not possible. Using the transiliac dorsoventral screw position with special long screws, we achieved high mechanical triangular stability sufficient for pelvic ring fusion despite the large bony defect.
Find related publications in this database (using NLM MeSH Indexing)
Adult -
Bone Plates -
Bone Screws -
Female -
Fracture Fixation, Internal - instrumentationFracture Fixation, Internal - methods
Humans -
Ilium - surgery
Joint Instability - etiology
Magnetic Resonance Imaging -
Pelvic Bones - surgery
Pseudarthrosis - diagnosisPseudarthrosis - etiologyPseudarthrosis - radiographyPseudarthrosis - surgery
Punctures -
Sacroiliac Joint - radiography
Sacrum - surgery
Sepsis - complications
Titanium -
Tomography, X-Ray Computed -

Find related publications in this database (Keywords)
pelvic ring instability
septic pseudoarthrosis
lumbopelvic fixation
triangular osteosynthesis
septic destruction
© Med Uni Graz Impressum