A new technic for preventing post-puncture complications following diagnostic lumbar puncture
HNO. 1987; 35(4):172-174
Web of Science PubMed

 

Leading authors Med Uni Graz
Kainz Josef
Co-authors Med Uni Graz
Friedrich Gerhard
Altmetrics:

Dimensions Citations:

Plum Analytics:
Abstract:
We investigated the clinical relevance of a new lumbar-puncture technique for prevention of headache. The spinal meninges were penetrated with a conventional puncture-needle with its bevel adjusted parallel to the main fibre direction, contrary to that in the usual technique. We used this method in 12 patients and only 1 complained of headache. On the other hand 9 patients out of 12 suffered from headache after conventional lumbar-puncture. These results demonstrate that post-lumbar puncture headache can be prevented by this technique in a high proportion of patients.