Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Koestenberger, M; Cvirn, G; Nagel, B; Rosenkranz, A; Leschnik, B; Gamillscheg, A; Beitzke, A; Muntean, W.
Thrombin generation determined by calibrated automated thrombography (CAT) in pediatric patients with congenital heart disease.
Thromb Res. 2008; 122(1): 13-19. Doi: 10.1016/j.thromres.2007.08.016
Web of Science PubMed FullText FullText_MUG Google Scholar

 

Führende Autor*innen der Med Uni Graz
Koestenberger Martin
Co-Autor*innen der Med Uni Graz
Beitzke Albrecht
Cvirn Gerhard
Ehammer-Rosenkranz Andrea
Gamillscheg Andreas
Leschnik Bettina
Muntean Eugen
Nagel Bert Hermann Philipp
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
INTRODUCTION: Thrombin generation was studied in pediatric patients with congenital heart disease (CHD) undergoing cardiac surgery using the calibrated automated thrombography (CAT) in terms of the lag time until the onset of thrombin formation, time to thrombin peak maximum (TTP), endogenous thrombin potential (ETP), and thrombin peak height. The possible suitability to determine the coagulation status of these patients was investigated. MATERIALS AND METHODS: CAT data of 40 patients with CHD (age range from newborn to 18 years) were compared to data using standard coagulation parameters such as prothrombin (FII), antithrombin (AT), tissue factor pathway inhibitor (TFPI), prothrombin fragment 1.2 (F 1.2), thrombin-antithrombin (TAT), activated partial thromboplastin time (aPTT), and prothrombin time (PT). RESULTS: A significant positive correlation was seen between ETP and FII (p<0.01; r=0.369), as well as between peak height and F II (p<0.01; r=0.483). A significant negative correlation was seen between ETP and TFPI values (p<0.05; r=-0.225) while no significant correlation was seen between peak height and TFPI. A significant negative correlation was seen between F 1.2 generation and ETP (p<0.05; r=-0.254) and between F 1.2 generation and peak height (p<0.05; r=-0.236). No correlation was seen between AT and ETP or peak. CONCLUSIONS: Our data indicate that CAT is a good global test reflecting procoagulatory and inhibitory factors of the hemostatic system in pediatric patients with CHD.
Find related publications in this database (using NLM MeSH Indexing)
Adolescent -
Antithrombins - metabolism
Child -
Child, Preschool -
Heart Defects, Congenital - blood
Humans -
Infant -
Infant, Newborn -
Kinetics -
Partial Thromboplastin Time -
Peptide Fragments - blood
Prothrombin Time -
Thrombin - biosynthesis

Find related publications in this database (Keywords)
calibrated automated thrombography
thrombin generation
endogenous thrombin potential
prothrombin
cardiac surgery
congenital heart disease
© Med Uni Graz Impressum