Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Payer, M; Kirmeier, R; Jakse, N; Pertl, C; Wegscheider, W; Lorenzoni, M.
Surgical factors influencing mesiodistal implant angulation.
Clin Oral Implants Res. 2008; 19(3): 265-270. Doi: 10.1111/j.1600-0501.2007.01464.x
Web of Science PubMed FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Lorenzoni Martin
Payer Michael
Co-Autor*innen der Med Uni Graz
Jakse Norbert
Kirmeier Robert
Wegscheider Walther
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
The aim of this experimental study was to identify relevant surgical parameters influencing the mesiodistal angular deviation of dental implants. Pilot drillings of 2 mm diameter were performed in bovine ribs with a parallelometer. The subsequent preparation of the implant socket was performed freehand. Utilizing six different implant systems, at least 80 drillings per system of different diameters were performed. The pilot drillings were marked with 2 mm steel pins and cephalometric radiographs were taken. The mesiodistal angle between the longitudinal implant axis and the marked pilot drillings was measured and evaluated by a blinded investigator. To evaluate the influence of the surgeons' experience, their drillings were compared with those of a group of unexperienced surgeons. Additionally, the influence of drilling speed and size of bur steps on drilling accuracy were evaluated. The difference between the lowest value of 0.91 degrees of mesiodistal angular deviation found for 3i implants and the highest of 1.36 degrees for Ankylos implants was of low statistical significance (P=0.065). Drillings of experienced surgeons showed less deviation compared with those of a beginners group (P<0.0001). Higher deviations were measured when a bur size was skipped. Drillings performed at high speed showed significantly higher deviations than those with fewer rewinds per minute. In order to achieve precise implant angulation, all bur diameters available should be used. Utilizing low drilling speeds results in less mesiodistal deviation. The surgeon's experience seems to be the most relevant factor in precise implant placement.
Find related publications in this database (using NLM MeSH Indexing)
Analysis of Variance -
Animals -
Cattle -
Clinical Competence -
Dental High-Speed Equipment -
Dental High-Speed Technique - adverse effects
Dental Implantation, Endosseous - instrumentation Dental Implantation, Endosseous - methods
Dental Implants -
Dental Prosthesis Design -
Ribs - surgery
Statistics, Nonparametric -

Find related publications in this database (Keywords)
dental implant
implant angulation
implant deviation
surgical templates
© Med Uni Graz Impressum