Medizinische Universität Graz - Research portal

Logo MUG Resarch Portal

Selected Publication:

SHR Neuro Cancer Cardio Lipid Metab Microb

Uter, W; Hegewald, J; Kränke, B; Schnuch, A; Gefeller, O; Pfahlberg, A.
The impact of meteorological conditions on patch test results with 12 standard series allergens (fragrances, biocides, topical ingredients).
Br J Dermatol. 2008; 158(4): 734-739. Doi: 10.1111/j.1365-2133.2008.08448.x
Web of Science PubMed FullText FullText_MUG

 

Co-authors Med Uni Graz
Kränke Birger
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
BACKGROUND: Fluctuating irritability of the skin induced by low ambient temperature and humidity may compromise the reproducibility of patch testing. OBJECTIVES: To assess the impact of temperature and absolute humidity at the time of patch testing on the occurrence of irritant or doubtful (IR/?), weak positive (+) and (strong) positive (++/+++) reactions, respectively, among 12 allergens included in the German Standard Series. METHODS: Analysis of clinical data collected in the surveillance network IVDK (http://www.ivdk.org) between January 1993 and December 2001 (n = 73 691 patients) combined with meteorological data obtained by the national services in Germany and Austria. Multinomial logistic regression analysis was used to estimate the risk associated with temperature, absolute humidity and vapour pressure, respectively, adjusted for sex, age, atopic dermatitis and duration of patch test application. RESULTS: For low temperature and humidity, a relevant increase of IR/? reaction frequency was observed in the cases of paraben mix and (chloro-) methylisothiazolinone. Both IR/? and + reactions were significantly increased with respect to the allergens fragrance mix, oil of turpentine, methyldibromo glutaronitrile + phenoxyethanol and particularly formaldehyde, while ++/+++ reactions were hardly affected by weather conditions. CONCLUSIONS: The observed increase of IR/? reactions may be due to epidermal barrier function impairment. The impact of dry/cold weather on + reactions in terms of possibly false-positive reactions is restricted to few allergens. In the case of + reactions of unknown relevance, a re-test under warm conditions or verification tests such as the repeated open application test or the provocative use test may be recommendable.
Find related publications in this database (using NLM MeSH Indexing)
Adult -
Allergens - adverse effects
Dermatitis, Allergic Contact - etiology
Disinfectants - adverse effects
Europe -
False Positive Reactions -
Female -
Humans -
Humidity - adverse effects
Male -
Meteorological Concepts -
Patch Tests - methods
Perfume - adverse effects
Temperature -

Find related publications in this database (Keywords)
allergic contact dermatitis
epidemiology
patch testing
weather
© Med Uni GrazImprint