Stelzl, E; Muller, Z; Marth, E; Kessler, HH.
Rapid quantification of hepatitis B virus DNA by automated sample preparation and real-time PCR.
J Clin Microbiol. 2004; 42(6):2445-2449 Doi: 10.1128/JCM.42.6.2445-2449.2004 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Leading authors Med Uni Graz
Kessler Harald
Stelzl Evelyn
Co-authors Med Uni Graz
Marth Egon
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Monitoring of hepatitis B virus (HBV) DNA in serum by molecular methods has become the standard for assessment of the replicative activity of HBV. Several molecular assays for the detection and quantification of HBV DNA have been described. However, they usually lack automated sample preparation. Moreover, those assays, which are based on PCR, are limited by a short dynamic range (2 to 3 log units). In the present study, the use of RealArt HBV LC PCR Reagents in conjunction with automated extraction on the COBAS AMPLIPREP analyzer was evaluated. Members of an HBV proficiency program panel were tested; linearity, interassay, and intra-assay variations were determined. The performance of the assay in a routine clinical laboratory was evaluated with a total of 117 clinical specimens. When members of the HBV proficiency program panel were tested by the new molecular assay, the results were found to be within +/-0.5 log unit of the results obtained by reference laboratories. Determination of linearity resulted in a quasilinear curve over more than 6 log units. The interassay variation of the RealArt HBV LC PCR Reagents by use of the automated sample preparation protocol ranged from 16 to 73%, and the intra-assay variation ranged from 9 to 40%. When clinical samples were tested by the new assay with the automated sample preparation protocol and the results were compared with those obtained by the COBAS AMPLICOR HBV MONITOR Test with manual sample preparation, the results for 76% of all samples with positive results by both tests were found to be within +/-0.5 log unit and the results for another 18% were found to be within between 0.5 and 1.0 log unit. In conclusion, the real-time PCR assay with automated sample preparation proved to be suitable for the routine molecular laboratory and required less hands-on time.
Find related publications in this database (using NLM MeSH Indexing)
DNA, Viral - blood
Hepatitis B virus - genetics
Humans -
Polymerase Chain Reaction - methods

© Med Uni GrazImprint