Diagnostic accuracy of 3D time-of-flight MR angiography compared with digital subtraction angiography for follow-up of coiled intracranial aneurysms: influence of aneurysm size.
AJNR Am J Neuroradiol. 2007; 28(4):628-634 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText

 

Leading authors Med Uni Graz
Deutschmann Hannes
Co-authors Med Uni Graz
Augustin Michael
Fritz Gerald
Klein Guenther
Schoellnast Helmut
Simbrunner Josef
Altmetrics:

Dimensions Citations:

Plum Analytics:
Abstract:
3D time-of-flight MR angiography (3D TOF MRA) may be used as noninvasive alternative to digital subtraction angiography (DSA) for the follow-up of patients with intracranial aneurysms treated with Guglielmi detachable coils (GDCs). We aimed to determine the influence of aneurysm size and location on diagnostic accuracy of 3D TOF MRA for follow-up of intracranial aneurysms treated with GDCs. Two hundred and one 3D TOF MRAs in 127 consecutive patients with 136 aneurysms were compared with DSA as standard of reference. Sensitivity and specificity of 3D TOF MRA for detection of residual or reperfusion of the aneurysms was calculated with regard to aneurysm size and location. Overall sensitivity and specificity of MRA was 88.5% and 92.9%, respectively. Sensitivity was lower for aneurysms <or=5 mm (72.2%) and <or=3 mm (63.6%). In addition to the small aneurysm size, interpretation of MR angiograms was compromised by susceptibility artifacts at the air-bone interface, arterial overlap, and pulsation-induced artifacts. The small number of disagreements between MRA and DSA hampered reliable interpretation of the possible influence of aneurysm location on MRA accuracy. The sensitivity of 3D TOF MRA for detection of reperfusion or residual perfusion of coiled intracranial aneurysms varies considerably depending on the size of the aneurysms. No conclusions can be drawn regarding a possible influence of aneurysm location on diagnostic accuracy of 3D TOF MRA. These findings may influence the decision about whether to replace DSA by 3D TOF MRA for the follow-up of patients with intracranial aneurysms treated with GDCs.
Find related publications in this database (using NLM MeSH Indexing)
Adolescent -
Adult -
Aged -
Angiography, Digital Subtraction -
Artifacts -
Cerebral Angiography -
Contrast Media -
Embolization, Therapeutic -
Female -
Humans -
Imaging, Three-Dimensional -
Intracranial Aneurysm - diagnosis
Intracranial Aneurysm - pathology
Intracranial Aneurysm - therapy
Magnetic Resonance Angiography -
Male -
Middle Aged -
Reperfusion -
Sensitivity and Specificity -

© Med Uni GrazImprint