Mächler, H; Reiter, G; Perthel, M; Reiter, U; Bergmann, P; Zink, M; Rienmüller, R; Laas, J.
Influence of a tilting prosthetic mitral valve orientation on the left ventricular flow - an experimental in vivo magnetic resonance imaging study.
Eur J Cardiothorac Surg. 2007; 32(1):102-7 Doi: 10.1016/j.ejcts.2007.02.038 [OPEN ACCESS]
Web of Science PubMed FullText FullText_MUG

 

Leading authors Med Uni Graz
Mächler Heinrich
Co-authors Med Uni Graz
Reiter Gert
Reiter Ursula
Rienmüller Rainer
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
OBJECTIVE: Orientation-related monoleaflet mechanical valve flow and velocity studies in the downstream are limited in mitral valve replacement studies. METHODS: In five sheep, ventricular blood flow was visualized prior to the implantation of a Medtronic Hall tilting valve model. In six sheep, the implant orientation was either anatomical (disc aligned with the anterior leaflet) or anti-anatomical. The mitral subvalvular apparatus was preserved. Sheep were positioned within an 1.5 T field strength MR scanner (Magnetom Sonata; Siemens) to assess time-dependent three dimensional blood flow. RESULTS: The preoperative ventricular velocity profiles presented negligible individual variances. Streamlines passed homogeneously without any spatial differences in flow velocities into the left ventricle. Starting from the anatomical position, blood entered mainly through the major orifice of the mechanical valve. The single artificial leaflet mimicked the rudder effect of the natural anterior mitral leaflet, preventing blood streaming directly towards the septum. The area with inhomogeneous blood velocities in the ventricle increased but not significantly from the preoperative status. The non-axial inflow not directed directly to the apex converted to a similar helix as observed in the preoperative cases. Anti-anatomical orientation of the prosthesis caused a significant increase in turbulence immediately after passing the mitral prosthesis. The main stream was changed so significantly that the blood flow shifted towards the septum and caused higher velocities of the stream profiles and turbulence apically. CONCLUSIONS: To achieve optimal hemodynamics, orientation of the mitral tilting valve has to be considered carefully, as has been long known from aortic valve replacement studies.
Find related publications in this database (using NLM MeSH Indexing)
Animals - administration & dosage
Blood Flow Velocity - administration & dosage
Heart Valve Prosthesis - administration & dosage
Heart Valve Prosthesis Implantation - methods
Hemorheology - administration & dosage
Magnetic Resonance Imaging - methods
Mitral Valve - anatomy & histology, physiology, surgery
Sheep - administration & dosage
Ventricular Function, Left - administration & dosage

Find related publications in this database (Keywords)
mitral valve prosthesis
orientation
intra-ventricutar flow
magnetic resonance imaging