Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Weinberg, AM; Castellani, C; Arzdorf, M; Schneider, E; Gasser, B; Linke, B.
Osteosynthesis of supracondylar humerus fractures in children: a biomechanical comparison of four techniques.
Clin Biomech (Bristol, Avon). 2007; 22(5): 502-509. Doi: 10.1016/j.clinbiomech.2006.12.004
Web of Science PubMed FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Weinberg Annelie-Martina
Co-Autor*innen der Med Uni Graz
Castellani Christoph
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
BACKGROUND: Crossed k-wire osteosynthesis is a widely used procedure for displaced supracondylar humerus fractures in children, but the rate of secondary displacements is up to 31%. Alternative techniques including casts, elastic stable intramedullary nailing, and the fixateur extern, have been used, but there are no biomechanical data comparing these methods. We developed a biomechanical model to compare four osteosynthesis techniques for stabilizing supracondylar humerus fractures in children. METHODS: An osteotomy to simulate a fracture was made in a total of 32 adult cadaver humeri. The pseudofractures were then stabilized by crossed k-wires, elastic nailing, a fixateur extern with either k-wires, or Schanz screws. We measured the stiffness values in flexion and extension and torsion with static loading. The movements in cyclic loading were chosen to resemble the mechanism described in the development of a clinical cubitus varus. FINDINGS: No significant differences were found with static loading. With cyclic loading all methods showed an irreversible torsional deformation less than 20 degrees . Crossed k-wires and elastic nailing showed significantly lower reversible torsional deformation than the external fixateurs. INTERPRETATION: Our biomechanical data reveal that the crossed k-wires have the highest stiffness and lowest loss of reduction under cyclic loading. The external fixators proved to be good alternatives.
Find related publications in this database (using NLM MeSH Indexing)
Cadaver -
Child -
Elasticity -
Fracture Fixation, Internal - instrumentation
Humans - instrumentation
Humeral Fractures - physiopathology
Humerus - physiopathology
Stress, Mechanical - physiopathology
Treatment Outcome - physiopathology
Weight-Bearing - physiopathology

Find related publications in this database (Keywords)
children
humerus
supracondylar
biomechanics
ESIN
k-wire osteosynthesis
fixateur extern
© Med Uni Graz Impressum