Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

Gras, D; Mabo, P; Tang, T; Luttikuis, O; Chatoor, R; Pedersen, AK; Tscheliessnigg, HH; Deharo, JC; Puglisi, A; Silvestre, J; Kimber, S; Ross, H; Ravazzi, A; Paul, V; Skehan, D.
Multisite pacing as a supplemental treatment of congestive heart failure: preliminary results of the Medtronic Inc. InSync Study.
Pacing Clin Electrophysiol. 1998; 21(11 Pt 2): 2249-2255. Doi: 10.1111/j.1540-8159.1998.tb01162.x
Web of Science PubMed FullText FullText_MUG

 

Co-Autor*innen der Med Uni Graz
Tscheliessnigg Karlheinz
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
This report describes the initial results of the "InSync" study, a European and Canadian multicenter trial that examines the safety and efficacy of a multisite pacemaker (Medtronic InSync) and of left ventricular pacing leads (Medtronic 2187 and 2188) implanted via a cardiac vein as a supplemental treatment of refractory congestive heart failure. Over a 10-month period, the system was implanted successfully in 68 of the 81 (84%) patients who had been enrolled in the study. The 68 patients were, on average, 66 +/- 10 years old, had a mean left ventricular ejection fraction (LVEF) = 21% +/- 9%, and 63% were in NYHA functional Class III and 37% were in Class IV. No system implant related complication occurred. During follow-up, 7 of 10 patients who exited the study had died, 4 suddenly. There was a clinical benefit among surviving patients, which was corroborated by a significant improvement in NYHA functional class and in the Minnesota Living with Heart Failure Quality of Life Questionnaire Score (MLS) and by a longer distance covered during a 6-minute walk test. This clinical improvement was associated with a significant narrowing of the paced QRS complex during biventricular pacing, a significant decrease in the interventricular mechanical delay, and a trend towards an increase in the duration of ventricular filling. These encouraging preliminary results confirm the feasibility and reliability of this new multisite pacing system in the management of dilated cardiomyopathy and support the continuation of further evaluations of this complementary treatment of refractory congestive heart failure.
Find related publications in this database (using NLM MeSH Indexing)
Aged -
Cardiac Pacing, Artificial - methods
Cardiomyopathy, Dilated - therapy
Electrocardiography - therapy
Electrodes, Implanted - therapy
Equipment Design - therapy
Feasibility Studies - therapy
Female - therapy
Follow-Up Studies - therapy
Heart Failure, Congestive - therapy
Humans - therapy
Male - therapy
Pacemaker, Artificial - therapy
Time Factors - therapy

Find related publications in this database (Keywords)
pacing
heart failure
multisite pacing
left ventricular pacing
© Med Uni Graz Impressum