Semlitsch, G; Buchinger, W; Reiterer, E; Binter, G; Rainer, F.
Measurement of free triiodothyronine (FT3) using an electrochemiluminescence immunoassay in patients with autoantibodies to triiodothyronine
Acta Med Austriaca. 2000; 27(2):54-55 Doi: 10.1046/j.1563-2571.2000.00207.x
Web of Science PubMed FullText FullText_MUG

 

Co-authors Med Uni Graz
Fröhlich-Reiterer Elke
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Thyroid hormone autoantibodies may lead to abnormal values of free triiodothyronine (FT3) and free thyroxine (FT4) by interference with the radio immunoassay (RIA). We examined thyroid function in six patients with known triiodothyronine-binding autoantibodies using a RIA and an electro-chemiluminescence immunoassay (ECLIA). FT3 values measured by RIA were spuriously high, ECLIA measurement of FT3 led to correct values according to the patients' thyroid status. We conclude from these results that in patients with triiodothyronine-binding autoantibodies FT3 measurement by ECLIA is more useful than measurement by RIA.
Find related publications in this database (using NLM MeSH Indexing)
Adult -
Aged -
Autoantibodies - blood
Chemiluminescent Measurements - blood
Electrochemistry - methods
Female - methods
Humans - methods
Immunoassay - methods
Male - methods
Middle Aged - methods
Radioimmunoassay - methods
Reproducibility of Results - methods
Thyroid Diseases - blood
Thyrotropin - blood
Thyroxine - blood
Triiodothyronine - blood

Find related publications in this database (Keywords)
thyroid function
thyroid hormone autoantibodies
triiodothyronine
radioimmunoassay
electrochemiluminescence immunoassay
© Med Uni GrazImprint