Zhu, F; Schneditz, D; Levin, NW.
Sum of segmental bioimpedance analysis during ultrafiltration and hemodialysis reduces sensitivity to changes in body position.
Kidney Int. 1999; 56(2):692-699 Doi: 10.1046/j.1523-1755.1999.00588.x [OPEN ACCESS]
Web of Science PubMed FullText FullText_MUG Google Scholar

 

Leading authors Med Uni Graz
Schneditz Daniel
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
BACKGROUND: Bioimpedance, a noninvasive technique to analyze body composition, has attracted interest in determining body hydration in hemodialysis patients. However, the so-called whole-body (wrist-to-ankle) bioimpedance analysis (WBIA) is sensitive to changes in regional fluid distribution and tends to underestimate fluid changes during ultrafiltration in hemodialysis patients. The aim of this study was to show that volume changes calculated from a new approach, that is, segmental bioimpedance analysis (SBIA), are not affected by changes in body position. METHODS: Ten male patients (age 44 +/- 8 years, target weight 70.8 +/- 10 kg) were studied during their regular hemodialysis treatment while maintaining either a sitting or a supine body position throughout the study. Extracellular volume was calculated from extracellular resistance obtained from bioimpedance data measured for a range of frequencies (5 to 500 kHz) using the Xitron BIS4000B analyzer. Wrist-to-ankle measurements were compared with segmental arm, trunk, and leg measurements. RESULTS: Changes in extracellular volume estimated from wrist-to-ankle measurements only reached 80 +/- 13% and 65 +/- 17% of the actual change in body mass during sitting and supine dialysis treatments, respectively. However, when segmental measurements were analyzed, the calculated change in extracellular volume was 101 +/- 6% and 100 +/- 3% of the actual change in body mass during the sitting and supine treatments, respectively. CONCLUSIONS: SBIA properly identifies regional fluid changes and provides an appropriate measure of fluid changes caused by ultrafiltration and hemodialysis. The volume estimation based on the sum of segmental bioimpedance measurements is independent of body position, which is a prerequisite for applications in everyday practice.
Find related publications in this database (using NLM MeSH Indexing)
Adult -
Body Composition -
Electric Impedance -
Extracellular Space - metabolism
Humans - metabolism
Kidney Failure, Chronic - therapy
Male - therapy
Mathematics - therapy
Middle Aged - therapy
Posture - therapy
Renal Dialysis - therapy
Ultrafiltration - therapy
Water - metabolism

Find related publications in this database (Keywords)
body composition
hydration
extracellular volume
fluid distribution
whole-body bioimpedance analysis
© Med Uni GrazImprint