Schoellnast, H; Tillich, M; Deutschmann, HA; Deutschmann, MJ; Fritz, GA; Stessel, U; Schaffler, GJ; Uggowitzer, MM.
Abdominal multidetector row computed tomography: reduction of cost and contrast material dose using saline flush.
J Comput Assist Tomogr. 2003; 27(6):847-853 Doi: 10.1097/00004728-200311000-00002
Web of Science PubMed FullText FullText_MUG

 

Leading authors Med Uni Graz
Schoellnast Helmut
Co-authors Med Uni Graz
Deutschmann Hannes
Fritz Gerald
Schaffler Gottfried
Stessel Uwe
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
To evaluate the potential of a saline solution flush after the contrast material bolus in abdominal multidetector row CT (MDCT) in contrast material dose and cost reduction. Abdominal MDCT was performed in 78 patients who were assigned randomly to 2 groups receiving 120 mL nonionic contrast material (300 mgI/mL) alone or 100 mL of the same contrast material pushed with 40 mL of saline solution. Mean attenuation values for both groups were measured in the liver, the spleen, the pancreas, the portal vein, the inferior vena cava, and the abdominal aorta. Cost analyses were performed for both groups. There was no significant difference in parenchymal and vascular enhancement between both groups. The difference of the enhancement was 2 HU for the liver (P = 0.11), 2 HU for the spleen (P = 0.44), 3 HU for the pancreas (P = 0.38), 9 HU for the portal vein (P = 0.11), 3 HU for the inferior vena cava (P = 0.55), and 10 HU for the aorta (P = 0.06). Taking the costs of contrast material, saline solution, and disposal material into account, 7.30 dollars was saved by the patient using a saline solution flush. Using a saline flush after the contrast material bolus in abdominal MDCT allows an iodine dose reduction of approximately 6 g, or 17%, without impairing mean parenchymal and vascular enhancement and a cost reduction of 7.30 dollars per patient.
Find related publications in this database (using NLM MeSH Indexing)
Aged -
Contrast Media - administration & dosage
Cost Control -
Costs and Cost Analysis -
Female -
Humans -
Male -
Middle Aged -
Radiography, Abdominal - economics Radiography, Abdominal - methods
Sodium Chloride - administration & dosage
Tomography, X-Ray Computed - economics Tomography, X-Ray Computed - methods