Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Frilling, A; Stavrou, GA; Mischinger, HJ; de Hemptinne, B; Rokkjaer, M; Klempnauer, J; Thörne, A; Gloor, B; Beckebaum, S; Ghaffar, MF; Broelsch, CE.
Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection: a randomised prospective trial.
Langenbecks Arch Surg. 2005; 390(2):114-120 Doi: 10.1007/s00423-005-0543-x
Web of Science PubMed FullText FullText_MUG

 

Co-Autor*innen der Med Uni Graz
Mischinger Hans-Jörg
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Background and aims: A new carrier-bound fibrin sealant, TachoSil, is expected to be efficacious and safe as a haemostatic treatment in hepatic resection. Design: A prospective, randomised, open and controlled multicentre trial with intraoperative as well as postoperative assessment of efficacy and a 1 month follow-up period. Setting: Tertiary care centres. Patients/methods: One hundred and twenty-one patients requiring secondary haemostasis during planned liver resection. Patients with coagulation disorders and patients with persistent major bleeding after primary haemostatic measures were excluded. Intervention: Application of either carrier-bound fibrin sealant (n=59) or argon beamer (argon beam coagulator) (n=62) as secondary haemostatic treatment. Main outcome measure: Time to intraoperative haemostasis. Results: There was a significant superiority of TachoSil over argon beamer with regard to time to haemostasis (3.9 min, median 3.0, range 3-20 min vs 6.3 min, median 4.0, range 3-39 min) (P=0.0007). Haemoglobin concentration of drainage fluid was significantly lower on day 2 after surgery in TachoSil patients (1.1 mmol/l) than in argon beamer patients (2.3 mmol/l) (P=0.012). Overall, the frequency and causality of adverse events did not differ between the two treatment groups. Conclusion: TachoSil is superior to argon beamer in obtaining effective and fast intraoperative haemostasis. The safety data show TachoSil to be tolerable and safe for haemostatic treatment in liver resection.
Find related publications in this database (using NLM MeSH Indexing)
Drug Carriers -
Fibrin Tissue Adhesive - therapeutic use
Follow-Up Studies -
Hemostasis, Surgical -
Hemostatics - therapeutic use
Hepatectomy -
Humans -
Laser Coagulation -
Prospective Studies -
Treatment Outcome -

Find related publications in this database (Keywords)
liver resection
new carrier-bound fibrin sealant
© Med Uni Graz Impressum