Krachler, M; Domej, W.
Clinical laboratory parameters in osteoarthritic knee-joint effusions correlated to trace element concentrations.
Biol Trace Elem Res. 2001; 79(2):139-148 Doi: 10.1385/BTER:79:2:139
Web of Science PubMed FullText FullText_MUG

 

Co-Autor*innen der Med Uni Graz
Domej Wolfgang
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Interactions of clinical laboratory parameters with trace elements in knee-joint effusions might turn out to be potential diagnostic tool, increasing our pathophysiological understanding and knowledge on knee-joint effusions. Thus, the 11 clinical laboratory parameters, total protein, albumin, glucose, lactate dehydrogenase, uric acid, pH, rheumatoid factor, antistreptolysin, C-reactive protein, leukocyte, and erythrocyte counts were determined in 39 osteoarthritic knee-joint effusions and in corresponding sera. Additionally, concentrations of the 17 trace elements barium, beryllium, calcium, cadmium, cesium, copper, lanthanum, lithium, magnesium, molybdenum, lead, rubidium, antimony, tin, strontium, thallium, and zinc in both effusions and corresponding sera were quantified by inductively coupled plasma-mass spectrometry. Concentrations of most laboratory parameters in synovial fluid were within the normal ranges for serum. However, concentrations of total protein and albumin in effusions were distinctly lower than in sera of healthy adults. Results for rheumatoid factor, antistreptolysin, and C-reactive protein in the effusions were below their corresponding threshold values for serum. An indicator for inflammation, the leukocyte count had a median < 6.3 G/L. The erythrocyte count (median: < 0.06 T/L) revealed a very low presence of red blood cells in the effusions. Total protein concentrations and lactate dehydrogenase activity in the effusions correlated positively with effusion copper (r = 0.61 and 0.66) and effusion zinc (r = 0.71 and 0.49). For cesium, a negative correlation in both sera (r = -0.44) and effusions (r = -0.44) with LDH activity could be established. Concentrations of rubidium, strontium, and cesium responded to albumin concentrations in sera and in effusions, establishing an inverse correlation. All other trace elements showed no or only weak associations with the clinical laboratory parameters determined. Although distinct relationships between trace element concentrations and clinical laboratory parameters in knee-joint effusions exist, the clinical relevance of these findings needs to be further elucidated.
Find related publications in this database (using NLM MeSH Indexing)
Adult -
Aged -
Aged, 80 and over -
Albumins - metabolism
Chemistry, Clinical - methods
Female - methods
Humans - methods
Hydrogen-Ion Concentration - methods
Joints - metabolism
Knee - metabolism
L-Lactate Dehydrogenase - metabolism
Male - metabolism
Middle Aged - metabolism
Osteoarthritis - blood
Trace Elements - analysis
Zinc - analysis

Find related publications in this database (Keywords)
clinical laboratory parameters
trace elements
synovial fluid
knee-joint effusions
serum
osteoarthritis
chronic knee synovitis
© Med Uni Graz Impressum