PURPOSE: To determine the frequency and location of venous air emboli that occur with the use of electron-beam computed tomographic (CT) studies of the chest. MATERIALS AND METHODS: Findings from 677 patients who underwent chest electron-beam CT with intravenous administration of contrast material were reviewed. Unenhanced CT studies were performed in 127 (18.8%) of these patients while the intravenous cannula was in place but before injection of contrast material. RESULTS: Air emboli were observed on CT studies in 79 (11.7%) of 677 patients. Emboli were small (up to three air bubbles less than 1 cm in diameter) in 70 (10.3%) patients and were moderate (more than three air bubbles or bubbles 1-2 cm in diameter) in nine (1.3%) patients. Air emboli were located in the main pulmonary artery (n = 54 [8.0%]), superior vena cava (n = 12 [1.8%]), right ventricle (n = 10 [1.5%]), subclavian or brachiocephalic vein (n = 6 [0.9%]), and right atrium (n = 5 [0.7%]). Seven patients (1.0%) had emboli in more than one location. Air emboli were depicted on unenhanced CT scans of seven (5.5%) of 127 patients. No association was found between the frequency of air embolism and injection flow, injection site, or amount or type of contrast agent. CONCLUSION: Intravenous administration of contrast material may cause small to moderate-sized air emboli. Knowledge of the common locations of emboli can help radiologists distinguish them from image artifacts or paravasal air collections.
Find related publications in this database (using NLM MeSH Indexing)
Brachiocephalic Veins - radiography
Contrast Media - administration and dosage
Embolism, Air - etiology
Heart Ventricles - radiography
Humans - radiography
Injections, Intravenous - adverse effects
Iohexol - analogs and derivatives
Pulmonary Artery - radiography
Radiography, Thoracic - radiography
Subclavian Vein - radiography
Tomography, X-Ray Computed - adverse effects
Triiodobenzoic Acids - diagnostic use
Vena Cava, Superior - radiography

© Med Uni GrazImprint