Grechenig, W; Peicha, G; Clement, HG; Preidler, KW.
Ultrasonographic localization of a displaced screw in the carpal canal. A case report.
Acta Radiol. 1999; 40(6):625-627 Doi: 10.3109/02841859909175599 (- Case Report)
Web of Science PubMed FullText FullText_MUG

 

Leading authors Med Uni Graz
Grechenig Wolfgang
Co-authors Med Uni Graz
Clement Hans Gunther
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
We present a case of a 65-year-old patient with a surgically treated distal radius fracture. At 5-month follow-up, conventional radiography revealed breakage of the plate and a screw displaced into the volar soft tissue. Preoperative ultrasonography including dynamic assessment of the tendons showed the screw intratendinously as a hyperechogenic structure with repetitive echoes. This unusual localization was proven by surgery. Dynamic ultrasonography played an important diagnostic role in the localization of the loosened and displaced osteosynthetic material.
Find related publications in this database (using NLM MeSH Indexing)
Aged -
Bone Plates -
Bone Screws -
Equipment Failure -
Foreign-Body Migration - etiology Foreign-Body Migration - surgery Foreign-Body Migration - ultrasonography
Fracture Fixation, Internal - instrumentation
Humans -
Male -
Postoperative Complications - etiology Postoperative Complications - surgery
Radius Fractures - radiography Radius Fractures - surgery
Wrist - radiography Wrist - ultrasonography

Find related publications in this database (Keywords)
Radius Fracture
Hardware Displacement
Ultrasonography