Selected Publication:
SHR
Neuro
Cancer
Cardio
Lipid
Metab
Microb
Wendelstein, J; Kohnen, T; Casazza, M; Heath, M; Riaz, KM; Cooke, DL; Hoffmann, P; Langenbucher, A.
Update on Biometry and Lens Calculation - A Review of the Basic Principles and New Developments.
Klin Monbl Augenheilkd. 2022; 239(8): 960-970.
Doi: 10.1055/a-1896-0738
Web of Science
PubMed
FullText
FullText_MUG
- Co-authors Med Uni Graz
-
Casazza Marina
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- These days, accurate calculation of artificial lenses is an important aspect of patient management. In addition to the classic theoretical optical formulae there are a number of new approaches, most of which are available as online calculators. This review aims to explain the background of artificial lens calculation and provide an update on study results based on the latest calculation approaches. Today, optical biometry provides the computational basis for theoretical optical formulae, ray tracing, and also empirical approaches using artificial intelligence. Manufacturer information on IOL design and IOL power recorded as part of quality control could improve calculations, especially for higher IOL powers. With modern measurement data, there is further potential for improvement in the determination of the axial length to the retinal pigment epithelium and by adopting a sum-of-segment approach. With the available data, the cornea can be assumed to be a thick lens. The Kane formula, the EVO 2.0 formula, the Castrop formula, the PEARL-DGS, formula and the OKULIX calculation software provide consistently good results for artificial lens calculations. Excellent refractive results can be achieved using these tools, with approximately 80% having an absolute prediction error within 0.50 dpt, at least in highly selected study populations. The Barrett Universal II formula also produces excellent results in the normal and long axial length range. For eyes with short axial lengths, the use of Barrett Universal II should be reconsidered; in this case, one of the methods mentioned above is preferable. Second Eye Refinement can also be considered in this patient population, in conjunction with established classic third generation formulae.
- Find related publications in this database (using NLM MeSH Indexing)
-
Artificial Intelligence - administration & dosage
-
Axial Length, Eye - diagnostic imaging
-
Biometry - administration & dosage
-
Cornea - administration & dosage
-
Humans - administration & dosage
-
Lenses, Intraocular - administration & dosage
-
Optics and Photonics - administration & dosage
-
Phacoemulsification - administration & dosage
-
Refraction, Ocular - administration & dosage
-
Retrospective Studies - administration & dosage
- Find related publications in this database (Keywords)
-
biometry
-
cataract
-
IOL
-
lens calculation
-
IOL formula