Advanced 3D-Printed Capstan Clamping System for Accurate Uniaxial Tensile Testing of Biological Soft Tissues
APPL SCI-BASEL. 2024; 14(24): 11537 Doi: 10.3390/app142411537
Web of Science FullText FullText_MUG

 

Leading authors Med Uni Graz
Hammer Niels
Co-authors Med Uni Graz
Antipova Veronica Alexandra
Lin Alvin Curtis
Altmetrics:

Dimensions Citations:
Plum Analytics:


Scite (citation analytics):

Abstract:
Featured Application This study introduces a 3D-printed capstan-based clamping system that enhances uniaxial tensile testing of tendon tissues by reducing stress concentrations and preventing premature failures at the clamping region, resulting in more reliable biomechanical data.Abstract Standardized testing methods for the mechanical characterization of biological soft tissues remain underdeveloped in several domains. Existing clamping methods often induce high stress levels in the clamping region, thereby affecting experimental outcomes. This study introduces a 3D-printed clamping system based on the capstan principle. The capstan system was designed and manufactured using 3D printing technology and optimized to minimize the required gripping pressure while maintaining the natural, non-tapered state of specimens. This optimization helps reduce experimental artifacts and prevents premature tissue failure in the clamping region caused by local stress peaks. Usability trials were conducted using human flexor digitorum profundus (FDP) tendons (n = 15). Results showed that 80% of the tendons failed at the midpoint region, indicating the desired load distribution achieved by the clamping mechanism. The elastic moduli, averaging 316.18 +/- 86.73 MPa, and failure load properties, averaging 79.25 +/- 19.10 MPa, fell within the range of FDP values reported by other researchers, thereby supporting the validity of the capstan design. Capstan clamping offers a promising add-on for biomechanical testing of soft tissues. Further development is necessary to tailor the clamping design to various tissue geometries and to address issues related to tissue moisture regulation, thereby enhancing the reliability and versatility of the clamping system.

Find related publications in this database (Keywords)
3D printing
biomechanical properties
capstan principle
clamping
material slippage
soft tissue
stress concentration
tensile testing