García-Morales, JM; Tortamano-Neto, P; Todescan, FF; de, Andrade, JC; Marotti, J; Zezell, DM.
Stability of dental implants after irradiation with an 830-nm low-level laser: a double-blind randomized clinical study.
Lasers Med Sci. 2012; 27(4): 703-11. Doi: 10.1007/s10103-011-0948-4
Web of Science PubMed FullText FullText_MUG

 

Co-Autor*innen der Med Uni Graz
Marotti Großhausen Juliana
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Little is known about the benefits of low-level laser therapy (LLLT) on improvement of stability of dental implants. The aim of this randomized clinical study was to assess the LLLT effect on implants stability by means of resonance frequency analysis (RFA). Thirty implants were distributed bilaterally in the posterior mandible of eight patients. At the experimental side, the implants were submitted to LLLT (830 nm, 86 mW, 92.1 J/cm(2), 0.25 J, 3 s/point, at 20 points), and on the control side, the irradiation was simulated (placebo). The first irradiation was performed in the immediate postoperative period, and it was repeated every 48 h in the first 14 days. The initial implant stability quotient (ISQ) of the implants was measured by means of RFA. New ISQ measurements were made after 10 days, 3, 6, 9, and 12 weeks. The initial ISQ values ranged from 65-84, with a mean of 76, undergoing a significant drop in stability from the 10th day to the 6th week in the irradiated group, and presenting a gradual increase from the 6th to the 12th week. The highest ISQ values were observed on the 10th day in the irradiated group, and the lowest in the 6th week in both groups. Under the conditions of this study, no evidence was found of any effect of LLLT on the stability of the implants when measured by RFA. Since high primary stability and good bone quality are of major relevancy for a rigid bone-implant interface, additional LLLT may have little impact macroscopically.
Find related publications in this database (using NLM MeSH Indexing)
Adult - administration & dosage
Dental Implantation, Endosseous - methods
Dental Implants - administration & dosage
Dental Stress Analysis - administration & dosage
Denture Retention - administration & dosage
Double-Blind Method - administration & dosage
Female - administration & dosage
Follow-Up Studies - administration & dosage
Humans - administration & dosage
Intention to Treat Analysis - administration & dosage
Low-Level Light Therapy - methods
Male - administration & dosage
Mandible - surgery
Materials Testing - administration & dosage
Middle Aged - administration & dosage
Osseointegration - administration & dosage
Young Adult - administration & dosage

Find related publications in this database (Keywords)
Bone repair
Implants
Laser therapy
Primary stability