Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Haselhuhn, K; Marotti, J; Tortamano, P; Weiss, C; Suleiman, L; Wolfart, S.
Assessment of the stress transmitted to dental implants connected to screw-retained bars using different casting techniques.
J Oral Implantol. 2014; 40(6): 641-8. Doi: 10.1563/AAID-JOI-D-12-00029
Web of Science PubMed FullText FullText_MUG

 

Co-Autor*innen der Med Uni Graz
Marotti Großhausen Juliana
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Passive fit of the prosthetic superstructure is important to avoid complications; however, evaluation of passive fit is not possible using conventional procedures. Thus, the aim of this study was to check and locate mechanical stress in bar restorations fabricated using two casting techniques. Fifteen patients received four implants in the interforaminal region of the mandible, and a bar was fabricated using either the cast-on abutment or lost-wax casting technique. The fit accuracy was checked according to the Sheffield's test criteria. Measurements were recorded on the master model with a gap-free, passive fit using foil strain gauges both before and after tightening the prosthetic screws. Data acquisition and processing was analyzed with computer software and submitted to statistical analysis (ANOVA). The greatest axial distortion was at position 42 with the cast-on abutment technique, with a mean distortion of 450 μm/m. The lowest axial distortion occurred at position 44 with the lost-wax casting technique, with a mean distortion of 100 μm/m. The minimal differences between the means of axial distortion do not indicate any significant differences between the techniques (P = 0.2076). Analysis of the sensor axial distortion in relation to the implant position produced a significant difference (P < 0.0001). Significantly higher measurements were recorded in the axial distortion analysis of the distal sensors of implants at the 34 and 44 regions than on the mesial positions at the 32 and 42 regions (P = 0.0481). The measuring technique recorded axial distortion in the implant-supported superstructures. Distortions were present at both casting techniques, with no significant difference between the sides.
Find related publications in this database (using NLM MeSH Indexing)
Dental Abutments - administration & dosage
Dental Arch - pathology
Dental Casting Technique - administration & dosage
Dental Implants - administration & dosage
Dental Impression Technique - administration & dosage
Dental Marginal Adaptation - administration & dosage
Dental Prosthesis, Implant-Supported - administration & dosage
Denture Retention - instrumentation
Humans - administration & dosage
Mandible - pathology
Software - administration & dosage
Stress, Mechanical - administration & dosage
Torque - administration & dosage
Waxes - chemistry

Find related publications in this database (Keywords)
dimensional measurements
implant-supported dentures
passive fit
prosthetic screw
© Med Uni Graz Impressum