Medizinische Universität Graz - Research portal

Logo MUG Resarch Portal

Selected Publication:

SHR Neuro Cancer Cardio Lipid Metab Microb

Talakić, E; Kaufmann-Bühler, AK; Igrec, J; Adelsmayr, G; Janisch, M; Döller, C; Geyer, E; Lackner, K; Fuchsjäger, M; Schöllnast, H.
Perfusion Computed Tomography in Rectal Carcinoma: Influence of Optimization of the Patlak Range on Calculation of Equivalent Blood Volume and Flow Extraction.
J COMPUT ASSIST TOMO. 2023; 47(6): 850-855. Doi: 10.1097/RCT.0000000000001506
Web of Science PubMed FullText FullText_MUG

 

Leading authors Med Uni Graz
Fuchsjäger Michael
Talakic Emina
Co-authors Med Uni Graz
Adelsmayr Gabriel
Döller Carmen
Igrec Jasminka
Janisch Michael August Johann
Kaufmann-Bühler Ann-Katrin
Lackner Karoline
Schoellnast Helmut
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
PURPOSE: The aim of the study is to assess the influence of manual adjustment of the Patlak range in computed tomography (CT) perfusion analysis of rectal carcinoma compared with default range of the perfusion software. METHODS: This study was approved by the institutional review board and informed consent was obtained. Twenty-one patients (12 male, 9 female; mean age ± SD, 59 ± 11 years) with rectal cancer were included and underwent perfusion CT before preoperative chemoradiotherapy. Equivalent blood volume (BV) and flow-extraction (FE) were calculated using the Patlak plot model. Two perfusion sets were calculated per patient, a perfusion set using the default setting as provided by the software (dBV, dFE) and an optimized perfusion set after manual adaption of the Patlak range (aBV, aFE), which was limited to the intravascular space clearance of contrast to the extravascular space. Perfusion values calculated with both methods were compared for significance in differences using the Wilcoxon test. A P value of 0.05 or less was defined as statistically significant. RESULTS: Adjustment of the Patlak range statistically significantly influenced BV and FE calculation. Median dBV was 23.2 mL/100 mL (interquartile range [IQR], 12.1 mL/100 mL), whereas median aBV was 20.3 mL/100 mL (IQR, 10.9 mL/100 mL). The difference in BV was statistically significant ( P = 0.021). Median dFE was 8.3 mL/min/100 mL (IQR, 4.7 mL/min/100 mL), whereas median aFE was 15.4 mL/min/100 mL (IQR, 5.8 mL/min/100 mL). The difference in FE was statistically significant ( P < 0.001). CONCLUSIONS: Our findings indicate that in perfusion CT of rectal carcinoma, adjustment of the Patlak range may significantly influence BV and FE compared with default setting of the software. This may contribute to standardization in the use of this technique for functional imaging of rectal cancer.
Find related publications in this database (using NLM MeSH Indexing)
Humans - administration & dosage
Male - administration & dosage
Female - administration & dosage
Tomography, X-Ray Computed - methods
Rectal Neoplasms - diagnostic imaging, therapy
Blood Volume - administration & dosage
Perfusion - administration & dosage
Carcinoma - administration & dosage

Find related publications in this database (Keywords)
rectal cancer
multidetector computed tomography
perfusion imaging
© Med Uni GrazImprint