van Mourik, MJW; Zaar, DVJ; Smulders, MW; Heijman, J; Lumens, J; Dokter, JE; Passos, VL; Schalla, S; Knackstedt, C; Schummers, G; Gjesdal, O; Edvardsen, T; Bekkers, SCAM.
Adding Speckle-Tracking Echocardiography to Visual Assessment of Systolic Wall Motion Abnormalities Improves the Detection of Myocardial Infarction
J AM SOC ECHOCARDIOG. 2019; 32(1): 65-73.
Doi: 10.1016/j.echo.2018.09.007
Web of Science
PubMed
FullText
FullText_MUG
- Co-authors Med Uni Graz
-
Heijman Jordi
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- Background: The aim of this study was to investigate whether speckle-tracking echocardiography (STE) improves the detection of myocardial infarction (MI) over visual assessment of systolic wall motion abnormalities (SWMAs) using delayed enhancement cardiac magnetic resonance imaging as a reference. Methods: Transthoracic echocardiography was performed in 95 patients with first ST segment elevation MI 110 days (interquartile range, 97-171 days) after MI and in 48 healthy control subjects. Two experienced observers independently assessed SWMAs. Separately, longitudinal peak negative, peak systolic, end-systolic, global strain, and strain rate were measured and averaged for the American Heart Association-recommended coronary artery perfusion territories. Receiver operating characteristic analysis was used to determine a single optimal cutoff value for each strain parameter. The diagnostic accuracy of an algorithm combining visual assessment and STE was evaluated. Results: Median infarct size and transmurality were 15% (interquartile range, 7%-24%) and 64% (interquartile range, 46%-78%), respectively. Sensitivity, specificity, and accuracy of visual assessment to detect MI were 74% (95% CI, 63%-82%), 85% (95% CI, 72%-93%), and 78% (95% CI, 70%-84%), respectively. Among the strain parameters, SR had the highest diagnostic accuracy (area under the curve, 0.88; 95% CI, 0.83-0.94; cutoff value, -0.97 sec(-1)). The combination with STE improved sensitivity compared with visual assessment alone (94%; 95% CI, 86%-97%; P < .001), minimally affecting specificity (79%; 95% CI, 65%-89%; P = .607). Overall accuracy improved to 89% (95% CI, 82%-93%; P = .011). Multivariate analysis accounting for age and sex demonstrated that SR was independently associated with MI (odds ratio, 2.0; 95% CI, 1.6-2.7). Conclusions: The sensitivity and diagnostic accuracy of visually detecting chronic MI by assessing SWMAs are moderate but substantially improve when adding STE.
- Find related publications in this database (Keywords)
-
Myocardial infarction
-
Transthoracic echocardiography
-
Deformation analysis
-
Strain
-
Speckle-tracking echocardiography
-
Cardiac magnetic resonance imaging