Eichenlaub, M; Pleus, S; Rothenbühler, M; Bailey, TS; Bally, L; Brazg, R; Bruttomesso, D; Diem, P; Eriksson, Boija, E; Fokkert, M; Haug, C; Hinzmann, R; Jendle, J; Klonoff, DC; Mader, JK; Makris, K; Moser, O; Nichols, JH; Nørgaard, K; Pemberton, J; Selvin, E; Spanou, L; Thomas, A; Tran, NK; Witthauer, L; Slingerland, RJ; Freckmann, G.
Comparator Data Characteristics and Testing Procedures for the Clinical Performance Evaluation of Continuous Glucose Monitoring Systems.
Diabetes Technol Ther. 2024; 26(4):263-275 Doi: 10.1089/dia.2023.0465 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Co-Autor*innen der Med Uni Graz
Mader Julia
Moser Othmar
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Comparing the performance of different continuous glucose monitoring (CGM) systems is challenging due to the lack of comprehensive guidelines for clinical study design. In particular, the absence of concise requirements for the distribution of comparator (reference) blood glucose (BG) concentrations and their rate of change (RoC) that are used to evaluate CGM performance, impairs comparability. For this article, several experts in the field of CGM performance testing have collaborated to propose characteristics of the distribution of comparator measurements that should be collected during CGM performance testing. Specifically, it is proposed that at least 7.5% of comparator BG concentrations are <70 mg/dL (3.9 mmol/L) and >300 mg/dL (16.7 mmol/L), respectively, and that at least 7.5% of BG-RoC combinations indicate fast BG changes with impending hypo- or hyperglycemia, respectively. These proposed characteristics of the comparator data can facilitate the harmonization of testing conditions across different studies and CGM systems and ensure that the most relevant scenarios representing real-life situations are established during performance testing. In addition, a study protocol and testing procedure for the manipulation of glucose levels are suggested that enable the collection of comparator data with these characteristics. This work is an important step toward establishing a future standard for the performance evaluation of CGM systems.
Find related publications in this database (using NLM MeSH Indexing)
Humans - administration & dosage
Blood Glucose - administration & dosage
Blood Glucose Self-Monitoring - methods
Continuous Glucose Monitoring - administration & dosage
Hyperglycemia - diagnosis, prevention & control

Find related publications in this database (Keywords)
Continuous glucose monitoring
Clinical performance evaluation
Standardization
Comparator data characteristics
Testing procedures
Glucose rate of change