Gewählte Publikation:
SHR
Neuro
Krebs
Kardio
Lipid
Stoffw
Microb
Sheehan, MC; Collins, S; Wimmer, T; Gutta, NB; Monette, S; Durack, JC; Solomon, SB; Srimathveeravalli, G.
Non-Contact Irreversible Electroporation in the Esophagus With a Wet Electrode Approach
J BIOMECH ENG-T ASME. 2023; 145(9): 091004
Doi: 10.1115/1.4062491
[OPEN ACCESS]
Web of Science
PubMed
FullText
FullText_MUG
- Co-Autor*innen der Med Uni Graz
-
Wimmer Thomas
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- Our objective was to develop a technique for performing irreversible electroporation (IRE) of esophageal tumors while mitigating thermal damage to the healthy lumen wall. We investigated noncontact IRE using a wet electrode approach for tumor ablation in a human esophagus with finite element models for electric field distribution, joule heating, thermal flux, and metabolic heat generation. Simulation results indicated the feasibility of tumor ablation in the esophagus using an catheter mounted electrode immersed in diluted saline. The ablation size was clinically relevant, with substantially lesser thermal damage to the healthy esophageal wall when compared to IRE performed by placing a monopolar electrode directly into the tumor. Additional simulations were used to estimate ablation size and penetration during noncontact wet-electrode IRE (wIRE) in the healthy swine esophagus. A novel catheter electrode was manufactured and wIRE evaluated in seven pigs. wIRE was performed by securing the device in the esophagus and using diluted saline to isolate the electrode from the esophageal wall while providing electric contact. Computed tomography and fluoroscopy were performed post-treatment to document acute lumen patency. Animals were sacrificed within four hours following treatment for histologic analysis of the treated esophagus. The procedure was safely completed in all animals; post-treatment imaging revealed intact esophageal lumen. The ablations were visually distinct on gross pathology, demonstrating full thickness, circumferential regions of cell death (3.52 & PLUSMN; 0.89 mm depth). Acute histologic changes were not evident in nerves or extracellular matrix architecture within the treatment site. Catheter directed noncontact IRE is feasible for performing penetrative ablations in the esophagus while avoiding thermal damage.
- Find related publications in this database (Keywords)
-
tissue ablation
-
irreversible electroporation
-
joule heating
-
bioheat
-
Arrhenius thermal damage
-
finite element model
-
medical device design
-
animal experiments
-
in vivo validation