Prause, G; Kaltenböck, F; Doppler, R.
[Preclinical blood gas analysis. 2. Experience with three blood gas analyzers in emergency care].
Anaesthesist. 1998; 47(6):490-495 Doi: 10.1007/s001010050587
Web of Science PubMed FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Prause Gerhard
Co-Autor*innen der Med Uni Graz
Kaltenboeck Friedrich
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Within the last few years the use of Point-of-Care Analyzers increased. These testing is primarily performed in the emergency room, intensive care units, and in the operating room using small portable analyzers. The fact of being transportable and working with rechargeable or changable batteries and disposable cartridges caused us to use blood gas analysis in the prehospital setting. We tested three available blood gas analyzers: AVL OPTI 1, IRMA Blood Analyzer and the i-Stat Portlab System. All analyzers work with single-use cartridges and the calibration procedure is automatic. The AVL OPTI 1 uses a calibration gas and sucks in the blood by itself. The IRMA and the i-Stat system use a containing calibration gel, which must be removed from the sensory by injecting the blood sample. In all analyzers the results appear within 2-4 min on the screen. The OPTI 1 and the IRMA are able to print out the results automatically, the i-Stat uses an additional printer connected over an infrared adapter. During the observation period of 2 years more than 320 prehospital blood gas analyses were performed (200 with the OPTI 1.70 with IRMA and 50 with the i-Stat). All devices served their purpose. The main problems appeared with the application of the blood samples at the IRMA and the i-Stat. Because of this intricate procedures 21.4% and 20% of all tries failed. The time spent on the measurement was 2 to 5 minutes. All tested devices worked satisfactorily. Relating to the safety, the performance and the use the AVL OPTI 1 has to become the best notes. But this system is much more bigger and heavier than the others, especially the i-Stat Blood analyzer.
Find related publications in this database (using NLM MeSH Indexing)
Blood Gas Analysis - instrumentation
Calibration -
Emergency Medical Services -
Evaluation Studies as Topic -
Humans -

Find related publications in this database (Keywords)
Blood Gas Analyzer
Irma
Opti 1
I-Stat
Emergency Medicine