Selected Publication:
SHR
Neuro
Cancer
Cardio
Lipid
Metab
Microb
Hofer, E; Keplinger, F; Thurner, T; Wiener, T; Sanchez-Quintana, D; Climent, V; Plank, G.
A new floating sensor array to detect electric near fields of beating heart preparations.
Biosens Bioelectron, 21, 2232-2239
Doi: 10.1016/j.bios.2005.11.010
Web of Science
PubMed
FullText
FullText_MUG
- Leading authors Med Uni Graz
-
Hofer Ernst
- Co-authors Med Uni Graz
-
Plank Gernot
-
Wiener Thomas
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- A new flexible sensor for in vitro experiments was developed to measure the surface potential, Phi, and its gradient, E (electric near field), at given sites of the heart. During depolarisation, E describes a vector loop from which direction and magnitude of local conduction velocity theta can be computed. Four recording silver electrodes (14 microm x 14 microm) separated by 50 microm, conducting leads, and solderable pads were patterned on a 50 microm thick polyimide film. The conductive structures, except the electrodes, were isolated with polyimide, and electrodes were chlorided. Spacer pillars mounted on the tip fulfil two functions: they keep the electrodes 70 microm from the tissue allowing non-contact recording of Phi and prevent lateral slipping. The low mass (9.1 mg) and flexibility (6.33 N/m) of the sensor let it easily follow the movement of the beating heart without notable displacement. We examined the electrodes on criteria like rms-noise of Phi, signal-to-noise ratio of Phi and E, maximum peak-slope recording dPhi/dt, and deviation of local activation time (LAT) from a common signal and obtained values of 24-28 microV, 46 and 41 dB, 497-561 V/s and no differences, respectively. With appropriate data acquisition (sampling rate 100 kHz, 24-bit), we were able to record Phi and to monitor E and theta on-line from beat-to-beat even at heart rates of 600 beats/min. Moreover, this technique can discriminate between uncoupled cardiac activations (as occur in fibrotic tissue) separated by less than 1 mm and 1 ms.
- Find related publications in this database (using NLM MeSH Indexing)
-
Animals -
-
Body Surface Potential Mapping - instrumentation
-
Electrodes, Implanted - instrumentation
-
Electromagnetic Fields - instrumentation
-
Equipment Design - instrumentation
-
Equipment Failure Analysis - instrumentation
-
Guinea Pigs - instrumentation
-
Heart Conduction System - physiology
-
Heart Rate - physiology
-
In Vitro - physiology
-
Mice - physiology
-
Microelectrodes - physiology
-
Research Support, Non-U.S. Gov't - physiology
-
Transducers - physiology
- Find related publications in this database (Keywords)
-
high-density electrode array
-
micro mapping
-
conduction velocity