Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Mader, JK; Gölz, S; Bilz, S; Bramlage, P; Danne, T.
Controlling glycemic variability in people living with type 1 diabetes receiving insulin glargine 300 U/mL (Gla-300).
BMJ Open Diabetes Res Care. 2022; 10(4): Doi: 10.1136/bmjdrc-2022-002898 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Mader Julia
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Short-term glycemic variability is associated with the risk of hypoglycemia and hyperglycemia in people living with type 1 diabetes and can potentially affect clinical outcomes. Continuous glucose monitoring (CGM) is of increasing importance to evaluate glycemic variability in greater detail. Specific metrics for assessing glycemic variability were proposed, such as the SD of mean glucose level and associated coefficient of variation, and time in target glucose range to guide study designs, therapy and allow people with diabetes more transparency in interpreting their own CGM data. Randomized controlled trials (RCT) and real-world evidence provide complementary information about the efficacy/effectiveness and safety of interventions. Insulin glargine 300 U/mL (Gla-300) has a longer lasting and less variable action than insulin glargine U100 (Gla-100) with a lower risk of hypoglycemia. While insulin degludec U100 (iDeg-100) was associated with lower glucose values but more time below range in one randomized study compared with Gla-300, Gla-300 was associated with a higher per cent time in range, but also above the therapeutic range. However, a real-world study did not find differences during the day between Gla-300 and iDeg-100. The upcoming InRange RCT is the first head-to-head comparison of Gla-300 with iDeg-100 using CGM in an international population using CGM metrics as the primary endpoint. The non-interventional COMET-T real-world study will determine the real-world effectiveness of Gla-300 using CGM metrics and cover a broad spectrum of clinical practice decisions irrespective of the prior basal insulin.
Find related publications in this database (using NLM MeSH Indexing)
Blood Glucose - administration & dosage
Diabetes Mellitus, Type 1 - drug therapy
Humans - administration & dosage
Hypoglycemia - chemically induced, prevention & control
Hypoglycemic Agents - adverse effects
Insulin Glargine - adverse effects
Randomized Controlled Trials as Topic - administration & dosage

© Med Uni Graz Impressum