Medizinische Universität Graz - Research portal

Logo MUG Resarch Portal

Selected Publication:

SHR Neuro Cancer Cardio Lipid Metab Microb

Klein, L; Dorn, S; Amato, C; Heinze, S; Uhrig, M; Schlemmer, HP; Kachelrieß, M; Sawall, S.
Effects of Detector Sampling on Noise Reduction in Clinical Photon-Counting Whole-Body Computed Tomography.
Invest Radiol. 2020; 55(2):111-119 Doi: 10.1097/RLI.0000000000000616
Web of Science PubMed FullText FullText_MUG

 

Co-authors Med Uni Graz
Heinze Sarah
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
OBJECTIVES: Reconstructing images from measurements with small pixels below the system's resolution limit theoretically results in image noise reduction compared with measurements with larger pixels. We evaluate and quantify this effect using data acquired with the small pixels of a photon-counting (PC) computed tomography scanner that can be operated in different detector pixel binning modes and with a conventional energy-integrating (EI) detector. MATERIALS AND METHODS: An anthropomorphic abdominal phantom that can be extended to 3 sizes by adding fat extension rings, equipped with iodine inserts as well as human cadavers, was measured at tube voltages ranging from 80 to 140 kV. The images were acquired with the EI detector (0.6 mm pixel size at isocenter) and the PC detector operating in Macro mode (0.5 mm pixel size at iso) and ultrahigh-resolution (UHR) mode (0.25 mm pixel size at iso). Both detectors are components of the same dual-source prototype computed tomography system. During reconstruction, the modulation transfer functions were matched to the one of the EI detector. The dose-normalized contrast-to-noise ratio (CNRD) values are evaluated as a figure of merit. RESULTS: Images acquired in UHR mode achieve on average approximately 6% higher CNRD compared with Macro mode at the same spatial resolution for a quantitative D40f kernel. Using a sharper B70f kernel, the improvement increases to 21% on average. In addition, the better performance of PC detectors compared with EI detectors with regard to iodine imaging has been evaluated by comparing CNRD values for Macro and EI. Combining both of these effects, a CNRD improvement of up to 34%, corresponding to a potential dose reduction of up to 43%, can be achieved for D40f. CONCLUSIONS: Reconstruction of UHR data with a modulation transfer function below the system's resolution limit reduces image noise for all patient sizes and tube voltages compared with standard acquisitions. Thus, a relevant dose reduction may be clinically possible while maintaining image quality.
Find related publications in this database (using NLM MeSH Indexing)
Cadaver - administration & dosage
Humans - administration & dosage
Phantoms, Imaging - administration & dosage
Photons - administration & dosage
Radiographic Image Interpretation, Computer-Assisted - methods
Signal-To-Noise Ratio - administration & dosage
Tomography, X-Ray Computed - methods
Whole Body Imaging - methods

Find related publications in this database (Keywords)
tomography
x-ray computed tomography
contrast media
iodine
phantoms
imaging
radiation dosage
photon-counting CT
© Med Uni GrazImprint