Gewählte Publikation:
SHR
Neuro
Krebs
Kardio
Lipid
Stoffw
Microb
Rief, M; Raggam, R; Rief, P; Metnitz, P; Stojakovic, T; Reinthaler, M; Brodmann, M; März, W; Scharnagl, H; Silbernagel, G.
Comparison of Two Nuclear Magnetic Resonance Spectroscopy Methods for the Measurement of Lipoprotein Particle Concentrations.
Biomedicines. 2022; 10(7): 1766
Doi: 10.3390/biomedicines10071766
[OPEN ACCESS]
Web of Science
PubMed
FullText
FullText_MUG
- Führende Autor*innen der Med Uni Graz
-
Rief Martin
-
Scharnagl Hubert
- Co-Autor*innen der Med Uni Graz
-
Brodmann Marianne
-
März Winfried
-
Metnitz Philipp
-
Raggam Reinhard Bernd
-
Rief Peter
-
Silbernagel Günther
-
Stojakovic Tatjana
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- Background: Measuring lipoprotein particle concentrations may help to improve cardiovascular risk stratification. Both the lipofit (Numares) and lipoprofile (LabCorp) NMR methods are widely used for the quantification of lipoprotein particle concentrations. Objective: The aim of the present work was to perform a method comparison between the lipofit and lipoprofile NMR methods. In addition, there was the objective to compare lipofit and lipoprofile measurements of standard lipids with clinical chemistry-based results. Methods: Total, LDL, and HDL cholesterol and triglycerides were measured with ß-quantification in serum samples from 150 individuals. NMR measurements of standard lipids and lipoprotein particle concentrations were performed by Numares and LabCorp. Results: For both NMR methods, differences of mean concentrations compared to ß-quantification-derived measurements were ≤5.5% for all standard lipids. There was a strong correlation between ß-quantification- and NMR-derived measurements of total and LDL cholesterol and triglycerides (all r > 0.93). For both, the lipofit (r = 0.81) and lipoprofile (r = 0.84) methods, correlation coefficients were lower for HDL cholesterol. There was a reasonable correlation between LDL and HDL lipoprotein particle concentrations measured with both NMR methods (both r > 0.9). However, mean concentrations of major and subclass lipoprotein particle concentrations were not as strong. Conclusions: The present analysis suggests that reliable measurement of standard lipids is possible with these two NMR methods. Harmonization efforts would be needed for better comparability of particle concentration data.
- Find related publications in this database (Keywords)
-
nuclear magnetic resonance spectroscopy
-
ultracentrifugation
-
lipoproteins
-
lipoprotein subclasses
-
methods
-
analysis
-
very-low-density lipoproteins
-
low-density lipoproteins
-
high-density lipoproteins