Gewählte Publikation:
SHR
Neuro
Krebs
Kardio
Lipid
Stoffw
Microb
Isaac, SM; Jensen, R; Anagnostopoulou, P; Davies, JC; Gappa, M; Latzin, P; Saunders, C; Short, C; Singer, F; Stanojevic, S; Zwitserloot, A; Ratjen, F.
Evaluation of a multiple breath nitrogen washout system in children.
Pediatr Pulmonol. 2020; 55(8):2108-2114
Doi: 10.1002/ppul.24862
Web of Science
PubMed
FullText
FullText_MUG
- Co-Autor*innen der Med Uni Graz
-
Singer Florian
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- INTRODUCTION: The multiple breath nitrogen washout (MBW) test offers a sensitive measure of airway function. In this study we aim to (a) assess the validity of the EasyOne Pro LAB (MBWndd ) in an in vitro lung model, (b) assess the feasibility, repeatability, and reproducibility of MBWndd and (c) compare outcomes with the Exhalyzer D (MBWEM ) and body plethysmography. METHODS: In vitro, functional residual capacity (FRC) measurements were assessed using a lung model under quasi-physiological conditions and compared to measured FRC. In vivo plethysmography and MBW were performed in a prospective study of children at two visits (n = 45 healthy; n = 41 cystic fibrosis [CF]). Bland-Altman plots were used to compare agreement between FRC and lung clearance index (LCI) measurements. RESULTS: In vitro FRCndd measurements were repeatable but lung volumes were underestimated (mean relative difference -5.4% (limits of agreement [LA] -9.6%; -1.1%), 95% confidence interval (CI) -6.27; -4.45). In vivo, compared to plethysmography, FRCndd was consistently lower (-19.3% [-40.5; 1.9], 95% CI [-23.9; -14.7]), and showed a volume dependency. LCIndd values were also higher in children with smaller lung volumes. The within-test coefficient of variation of the FRCndd and LCIndd were 4.9% in health, and 5.6% and 6.9% in CF respectively. LCIndd was reproducible between-visits (mean relative difference [LA] -3.7% [-14.8, -7.5; 95% CI -6.6; -0.73] in health [n = 17] and 0.34% [-13.2, 22.8; 95% CI -5.0; 5.69] in CF [n = 23]). When calculated using the same algorithm, LCIndd was similar to LCIEM in health. CONCLUSIONS: MBWndd measurements are feasible, repeatable, and reproducible, however, MBW-derived outcomes are not interchangeable with MBWEM .
- Find related publications in this database (using NLM MeSH Indexing)
-
Adolescent - administration & dosage
-
Breath Tests - administration & dosage
-
Child - administration & dosage
-
Cystic Fibrosis - physiopathology
-
Female - administration & dosage
-
Humans - administration & dosage
-
Lung - physiopathology
-
Male - administration & dosage
-
Nitrogen - analysis
-
Plethysmography, Whole Body - administration & dosage
-
Reproducibility of Results - administration & dosage
-
Respiratory Function Tests - administration & dosage
- Find related publications in this database (Keywords)
-
function pulmonary testing