Medizinische Universität Graz - Research portal

Logo MUG Resarch Portal

Selected Publication:

SHR Neuro Cancer Cardio Lipid Metab Microb

Weis, J; Geiger, R; Kilo, J; Zimpfer, D.
Cormatrix® for vessel reconstruction in paediatric cardiac surgery-a word of caution.
Interact Cardiovasc Thorac Surg. 2022; 34(4): 597-603. Doi: 10.1093/icvts/ivab264 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Co-authors Med Uni Graz
Zimpfer Daniel
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
OBJECTIVES: The aim of this retrospective study was to determine if Cormatrix® (CM) represents a safe alternative to conventional patch materials used in congenital heart surgery. METHODS: A total of 57 paediatric patients who underwent cardiac surgery using an Extracellular Matrix Bioscaffold (CM) were categorized into 4 groups according to the patch implant location. Patch-related complications and reintervention rates were analysed. A subgroup of 18 patients was subsequently compared to a matched group of 36 patients who underwent similar surgical procedures with autologous pericardium as patch material. RESULTS: No patient died during hospitalization. There were 2 late deaths, not related to the implanted CM patch. Fourteen (66.7%) out of 21 patients with arterial patch plasty developed progressive vessel/right ventricular outflow tract stenosis or aneurysm. All 3 patients with a valved CM conduit developed haemodynamically relevant valve stenosis or regurgitation. A total of 18 (31.5%) patients needed reintervention and 12 (21.1%) related to CM. Four (7%) patients needed surgical treatment with operative removal of the stenosis. Redo valve replacement was performed on 2 (3.5%) patients. Six (10.5%) patients required an interventional cardiology procedure at a median interval of 5 months from surgery. The subgroup analysis revealed a significantly lower patch-related reintervention rate in patients treated with autologous pericardium when compared to CM (P = 0.006). CONCLUSIONS: CM is safe for atrial and ventricular defect closure. The use of CM for arterial vessel reconstruction is associated with higher reintervention rates when compared to autologous pericardium.
Find related publications in this database (using NLM MeSH Indexing)
Cardiac Surgical Procedures - adverse effects, methods
Child - administration & dosage
Heart Defects, Congenital - diagnostic imaging, surgery
Heart Ventricles - administration & dosage
Humans - administration & dosage
Pericardium - administration & dosage
Retrospective Studies - administration & dosage
Treatment Outcome - administration & dosage

Find related publications in this database (Keywords)
Cormatrix(R)
Small intestinal submucosa-extracellular matrix
Congenital heart defect Bioscaffold
© Med Uni GrazImprint