Medizinische Universität Graz - Research portal

Logo MUG Resarch Portal

Selected Publication:

SHR Neuro Cancer Cardio Lipid Metab Microb

Felli, A; Zeidler, P; Jilma, B; Opfermann, P; Holaubek, C; Zimpfer, D; Wadowski, PP; Steinlechner, B.
Different Heparin Contents in Prothrombin Complex Concentrates May Impair Blood Clotting in Outpatients With Ventricular Assist Devices Receiving Phenprocoumon.
J Cardiothorac Vasc Anesth. 2016; 30(1):96-101 Doi: 10.1053/j.jvca.2015.08.012
Web of Science PubMed FullText FullText_MUG

 

Co-authors Med Uni Graz
Zimpfer Daniel
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
OBJECTIVES: Prothrombin complex concentrates (PCCs) are used to rapidly reverse anticoagulation by oral vitamin K antagonists. They differ in the content of clotting factors, endogenous anticoagulants, and heparin. The authors hypothesized that PCCs' specific heparin content may compromise the hemostatic effect. DESIGN: Prospective ex-vivo investigation. SETTING: University hospital. PARTICIPANTS: Venous blood samples were obtained from 8 patients with implanted ventricular assist devices who also were receiving phenprocoumon. INTERVENTIONS: Four different 4-factor PCCs were added to patient blood to attain a calculated increase in prothrombin time by 20%, 40%, and 60% greater than baseline in paired experiments. MEASUREMENTS AND MAIN RESULTS: Clotting was measured using thromboelastometry and endogenous thrombin potential. Two heparin-containing PCCs prolonged the clotting times in a concentration-dependent manner compared with baseline (p<0.01) and compared with PCCs containing significantly less or no heparin (p<0.01). The PCCs containing low or no heparin enhanced the area under the curve of thrombin generation and peak thrombin several fold relative to the heparin-containing PCCs (p<0.01). One of the PCCs containing heparin even decreased peak thrombin generation by ~90% compared with baseline (p<0.01). PCC with low or no heparin shortened the lag phase (p<0.01), whereas 1 heparin containing PCC prolonged the lag phase by 66% (p<0.01). CONCLUSIONS: Physicians should be aware of the differences in heparin contents. Extrapolation of results from one agent to other PCC preparations may be difficult. Patients with an implanted left ventricular assist device and anticoagulated with vitamin-K antagonists could benefit from the use of PCC with low heparin content when surgery or bleeding requires emergency reversal. Further clinical studies are warranted.
Find related publications in this database (using NLM MeSH Indexing)
Adult - administration & dosage
Ambulatory Care - methods
Anticoagulants - administration & dosage, chemistry
Blood Coagulation - drug effects, physiology
Blood Coagulation Factors - administration & dosage, chemistry
Blood Coagulation Tests - methods
Drug Compounding - administration & dosage
Female - administration & dosage
Heart-Assist Devices - adverse effects
Heparin - administration & dosage, chemistry
Humans - administration & dosage
Male - administration & dosage
Middle Aged - administration & dosage
Phenprocoumon - administration & dosage
Prospective Studies - administration & dosage
Prothrombin Time - methods

Find related publications in this database (Keywords)
coumarin
prothrombin complex concentrate
thromboelastography
ventricular assist device
heparin
© Med Uni GrazImprint