Selected Publication:
SHR
Neuro
Cancer
Cardio
Lipid
Metab
Microb
Gustafsson, F; Mirza, KK; Pya, Y; Shaw, S; Diegeler, A; Netuka, I; Lavee, J; Garbade, J; Morshuis, M; Heatley, J; Saeed, D; Potapov, E; Schmitto, JD; Zimpfer, D, , ELEVATE, investigators.
Predictors of Physical Capacity 6 Months After Implantation of a Full Magnetically Levitated Left Ventricular Assist Device: An Analysis From the ELEVATE Registry.
J Card Fail. 2020; 26(7):580-587
Doi: 10.1016/j.cardfail.2020.04.004
Web of Science
PubMed
FullText
FullText_MUG
- Co-authors Med Uni Graz
-
Zimpfer Daniel
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- BACKGROUND: In patients with a continuous-flow left ventricular assist device, preimplant predictors of poor physical performance are not well-described. We aimed to identify predictors of inability to walk more than 300 m on 6-minute walk test (6MWT) 6 months after HeartMate 3 implantation. METHODS AND RESULTS: Using data from the European Registry of Patients Implanted With a Full Magnetically Levitated LVAD, patients with available 6MWT at 6 months after implantation were included (N = 194) and grouped according to 6MWT distance (6MWD) of >300 m (n = 150) or 6MWD of <300 m (n = 44). Patients walking <300 m were older (60 ± 10 vs 52 ± 12 years; P < .001), more often New York Heart Association functional class IV (63% vs 42%; P = .03), and more often had type 2 diabetes (43% vs 17%; P < .001) at implantation. Atrial fibrillation was seen in 57% in those with a 6MWT of <300 m vs 31% in those walking longer (P < .002). Further, hemoglobin and estimated glomerular filtration rate was lower in those walking <300 m (both P < .01). In multivariable regression analysis, independent predictors of a 6MWD of <300 m were: atrial fibrillation (odds ratio [OR], 3.22; 95% confidence interval [CI], 1.12-8.67), older age (OR for 10-year increment, 2.81; 95% CI, 1.55-5.07), New York Heart Association functional class IV (OR, 3.37; 95% CI, 1.27-8.98), and Interagency Registry for Mechanically Assisted Circulatory Support profile 1 or 2 (OR, 6.53; 95% CI, 1.92-22.19). CONCLUSIONS: Six months after HeartMate 3 implantation, 77% of patients walked >300 meters in 6 minutes. Apart from age and measures of heart failure severity, atrial fibrillation at implantation is an independent predictor of low 6MWD at 6 months after implantation.
- Find related publications in this database (using NLM MeSH Indexing)
-
Aged - administration & dosage
-
Diabetes Mellitus, Type 2 - administration & dosage
-
Heart Failure - epidemiology, therapy
-
Heart-Assist Devices - administration & dosage
-
Humans - administration & dosage
-
Registries - administration & dosage
-
Treatment Outcome - administration & dosage
- Find related publications in this database (Keywords)
-
Continuous-flow left ventricular assist device
-
Exercise
-
Work intolerance
-
6-minute walk test