Zimpfer, D; Schima, H; Czerny, M; Kasimir, MT; Sandner, S; Seebacher, G; Losert, U; Simon, P; Grimm, M; Wolner, E; Ehrlich, M.
Experimental stent-graft treatment of ascending aortic dissection.
Ann Thorac Surg. 2008; 85(2):470-3
Doi: 10.1016/j.athoracsur.2007.09.049
Web of Science
PubMed
FullText
FullText_MUG
- Leading authors Med Uni Graz
-
Zimpfer Daniel
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- BACKGROUND: This study assessed the feasibility of stent graft treatment of ascending aortic dissections in a porcine in vitro model. METHODS: The entire thoracic aortic aorta including the supraaortic branches was harvested from 12 adult pigs and an intimal tear was artificially created. The aortic annulus was then sewn into a silicon ring of a driving chamber. The distal aorta was connected to tubing with adjustable resistance elements. The circulation was driven by a hydraulic motor piston pump to mimic aortic flow and pressure. After creating a dissection by elevating the systolic aortic pressure to 180 mm Hg, a 2- x 2.6-cm covered stent graft was inserted through the brachiocephalic trunk using a specially designed delivery system. Stent graft placement was performed under continuous ultrasound control. RESULTS: The longitudinal length of the created ascending aortic dissection was 1.8 +/- 0.39 cm. Ultrasound studies revealed successful deployment of the stent graft and closure of the false lumen in all 12 cases. Diameter and area of the true lumen increased from 0.52 +/- 0.15 cm to 2.54 +/- 0.36 cm (p < 0.05) and from 0.78 +/- 0.27 cm2 to 5.13 +/- 1.35 cm2 (p < 0.05), respectively. The circumference of the true lumen increased from 4.50 +/- 0.52 cm to 7.96 +/- 1.2 cm (p < 0.05). Ultrasound studies also revealed uncompromised function of the aortic valve in all cases. No dislodging of stent grafts was observed. CONCLUSIONS: Given ideal anatomy, experimental stent graft placement for ascending aortic dissection is feasible and achieves complete closure of the false lumen.
- Find related publications in this database (using NLM MeSH Indexing)
-
Aneurysm, Dissecting - diagnostic imaging, surgery
-
Animals - administration & dosage
-
Aortic Aneurysm, Thoracic - diagnostic imaging, surgery
-
Blood Vessel Prosthesis - administration & dosage
-
Blood Vessel Prosthesis Implantation - methods
-
Disease Models, Animal - administration & dosage
-
Echocardiography, Doppler - administration & dosage
-
Feasibility Studies - administration & dosage
-
Probability - administration & dosage
-
Sensitivity and Specificity - administration & dosage
-
Stents - administration & dosage
-
Swine - administration & dosage