Geidl, L; Zrunek, P; Deckert, Z; Zimpfer, D; Sandner, S; Wieselthaler, G; Schima, H.
Usability and safety of ventricular assist devices: human factors and design aspects.
Artif Organs. 2009; 33(9):691-5 Doi: 10.1111/j.1525-1594.2009.00844.x
Web of Science PubMed FullText FullText_MUG

 

Co-authors Med Uni Graz
Zimpfer Daniel
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
The purpose of this study was the investigation of the usability and ergonomics of ventricular assist devices (VADs) in everyday usage. Patients with four different VAD types were observed. After implantation, instruction, and discharge from the hospital, the patients returned on a regular basis to the outpatient clinic, where the investigation took place. Data collection took place in two phases. In phase I home-released VAD patients were asked about perceived problems with the system at home. Additionally health-care professionals were interviewed to gather information on frequent VAD inconveniences and shortcomings. This inquiry resulted in a standardized self-assessment questionnaire and a manual skill test, which were performed in phase II by the whole collective (16 patients and ongoing). As a result, 38% of the patients disconnected parts of their system unintentionally at least once. All of them ascribed this problem to their own carelessness. Thirty-eight percent had to replace a cable. Seventy-five percent desired an additional cable strain relief. Thirty-eight percent suffered from rubbing of parts on the body. Sixty-three percent used a separate repository aside from the factory-provided transportation systems. The overall noise emission (pump, ventilators, and alarms) annoyed 56%; however, for 32% the alarm signals were too quiet to wake them up. No correlation between the assessed manual skills and the number of adverse events was found. To conclude, this preliminary study revealed considerable potential for improvements in the usability of ventricular assist systems.
Find related publications in this database (using NLM MeSH Indexing)
Adult - administration & dosage
Aged - administration & dosage
Clinical Alarms - administration & dosage
Consumer Product Safety - administration & dosage
Electric Power Supplies - administration & dosage
Equipment Design - administration & dosage
Equipment Failure - administration & dosage
Ergonomics - administration & dosage
Female - administration & dosage
Heart Failure - therapy
Heart-Assist Devices - adverse effects
Humans - administration & dosage
Male - administration & dosage
Middle Aged - administration & dosage
Motor Skills - administration & dosage
Patient Satisfaction - administration & dosage
Pilot Projects - administration & dosage
Self Care - administration & dosage
Surveys and Questionnaires - administration & dosage
Time Factors - administration & dosage
Treatment Outcome - administration & dosage

Find related publications in this database (Keywords)
Heart failure
Cardiac assist device
Blood pump
Usability
Safety