Selected Publication:
SHR
Neuro
Cancer
Cardio
Lipid
Metab
Microb
Minchev, G; Kronreif, G; Ptacek, W; Dorfer, C; Micko, A; Maschke, S; Legnani, FG; Widhalm, G; Knosp, E; Wolfsberger, S.
A novel robot-guided minimally invasive technique for brain tumor biopsies.
J Neurosurg. 2019; 1-9
Doi: 10.3171/2018.8.JNS182096
Web of Science
PubMed
FullText
FullText_MUG
- Leading authors Med Uni Graz
-
Wolfsberger Stefan
- Co-authors Med Uni Graz
-
Micko Alexander
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- OBJECTIVEAs decisions regarding tumor diagnosis and subsequent treatment are increasingly based on molecular pathology, the frequency of brain biopsies is increasing. Robotic devices overcome limitations of frame-based and frameless techniques in terms of accuracy and usability. The aim of the present study was to present a novel, minimally invasive, robot-guided biopsy technique and compare the results with those of standard burr hole biopsy.METHODSA tubular minimally invasive instrument set was custom-designed for the iSYS-1 robot-guided biopsies. Feasibility, accuracy, duration, and outcome were compared in a consecutive series of 66 cases of robot-guided stereotactic biopsies between the minimally invasive (32 patients) and standard (34 patients) procedures.RESULTSApplication of the minimally invasive instrument set was feasible in all patients. Compared with the standard burr hole technique, accuracy was significantly higher both at entry (median 1.5 mm [range 0.2-3.2 mm] vs 1.7 mm [range 0.8-5.1 mm], p = 0.008) and at target (median 1.5 mm [range 0.4-3.4 mm] vs 2.0 mm [range 0.8-3.9 mm], p = 0.019). The incision-to-suture time was significantly shorter (median 30 minutes [range 15-50 minutes] vs 37.5 minutes [range 25-105 minutes], p < 0.001). The skin incision was significantly shorter (median 16.3 mm [range 12.7-23.4 mm] vs 28.4 mm [range 20-42.2 mm], p = 0.002). A diagnostic tissue sample was obtained in all cases.CONCLUSIONSApplication of the novel instrument set was feasible in all patients. According to the authors' data, the minimally invasive robot-guidance procedure can significantly improve accuracy, reduce operating time, and improve the cosmetic result of stereotactic biopsies.
- Find related publications in this database (Keywords)
-
accuracy
-
biopsy
-
minimally invasive
-
robotic device
-
stereotaxy
-
oncology
-
surgical technique