Chirindel, A; Adebahr, S; Schuster, D; Schimek-Jasch, T; Schanne, DH; Nemer, U; Mix, M; Meyer, P; Grosu, AL; Brunner, T; Nestle, U.
Impact of 4D-(18)FDG-PET/CT imaging on target volume delineation in SBRT patients with central versus peripheral lung tumors. Multi-reader comparative study.
Radiother Oncol. 2015; 115(3):335-41
Doi: 10.1016/j.radonc.2015.05.019
Web of Science
PubMed
FullText
FullText_MUG
- Co-Autor*innen der Med Uni Graz
-
Brunner Thomas Baptist
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- PURPOSE: Evaluation of the effect of co-registered 4D-(18)FDG-PET/CT for SBRT target delineation in patients with central versus peripheral lung tumors. METHODS: Analysis of internal target volume (ITV) delineation of central and peripheral lung lesions in 21 SBRT-patients. Manual delineation was performed by 4 observers in 2 contouring phases: on respiratory gated 4DCT with diagnostic 3DPET available aside (CT-ITV) and on co-registered 4DPET/CT (PET/CT-ITV). Comparative analysis of volumes and inter-reader agreement. RESULTS: 11 cases of peripheral and 10 central lesions were evaluated. In peripheral lesions, average CT-ITV was 6.2 cm(3) and PET/CT-ITV 8.6 cm(3), resembling a mean change in hypothetical radius of 2 mm. For both CT-ITVs and PET/CT-ITVs inter reader agreement was good and unchanged (0.733 and 0.716; p=0.58). All PET/CT-ITVs stayed within the PTVs derived from CT-ITVs. In central lesions, average CT-ITVs were 42.1 cm(3), PET/CT-ITVs 44.2 cm(3), without significant overall volume changes. Inter-reader agreement improved significantly (0.665 and 0.750; p<0.05). 2/10 PET/CT-ITVs exceeded the PTVs derived from CT-ITVs by >1 ml in average for all observers. CONCLUSION: The addition of co-registered 4DPET data to 4DCT based target volume delineation for SBRT of centrally located lung tumors increases the inter-observer agreement and may help to avoid geographic misses.
- Find related publications in this database (using NLM MeSH Indexing)
-
Aged - administration & dosage
-
Aged, 80 and over - administration & dosage
-
Cone-Beam Computed Tomography - administration & dosage
-
Female - administration & dosage
-
Humans - administration & dosage
-
Lung Neoplasms - diagnostic imaging, pathology
-
Male - administration & dosage
-
Middle Aged - administration & dosage
-
Multimodal Imaging - administration & dosage
-
Positron-Emission Tomography - methods
- Find related publications in this database (Keywords)
-
4DPET/CT
-
SBRT
-
Central lung tumors
-