Brunner, TB; Nestle, U; Adebahr, S; Gkika, E; Wiehle, R; Baltas, D; Grosu, AL.
Simultaneous integrated protection : A new concept for high-precision radiation therapy.
Strahlenther Onkol. 2016; 192(12):886-894
Doi: 10.1007/s00066-016-1057-x
(- Case Report)
[OPEN ACCESS]
Web of Science
PubMed
FullText
FullText_MUG
- Leading authors Med Uni Graz
-
Brunner Thomas Baptist
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- OBJECTIVE: Stereotactic radiotherapy near serial organs at risk (OAR) requires special caution. A novel intensity-modulated radiotherapy (IMRT) prescription concept termed simultaneous integrated protection (SIP) for quantifiable and comparable dose prescription to targets very close to OAR is described. MATERIALS AND METHODS: An intersection volume of a planning risk volume (PRV) with the total planning target volume (PTV) defined the protection volume (PTVSIP). The remainder of the PTV represented the dominant PTV (PTVdom). Planning was performed using IMRT. Dose was prescribed to PTVdom according to ICRU in 3, 5, 8, or 12 fractions. Constraints to OARs were expressed as absolute and as equieffective doses at 2 Gy (EQD2). Dose to the gross risk volume of an OAR was to respect constraints. Violation of constraints to OAR triggered a planning iteration at increased fractionation. Dose to PTVSIP was required to be as high as possible within the constraints to avoid local relapse. RESULTS: SIP was applied in 6 patients with OAR being large airways (n = 2) or bowel (n = 4) in 3, 5, 8, and 12 fractions in 1, 3, 1, and 1 patients, respectively. PTVs were 14.5-84.9 ml and PTVSIP 1.8-3.9 ml (2.9-13.4 % of PTV). Safety of the plans was analyzed from the absolute dose-volume histogram (dose to ml). The steepness of dose fall-off could be determined by comparing the dose constraints to the PRVs with those to the OARs (Wilcoxon test p = 0.001). Constraints were respected for the corresponding OARs. All patients had local control at a median 9 month follow-up and toxicity was low. CONCLUSION: SIP results in a median dose of ≥100 % to PTV, to achieve high local control and low toxicity. Longer follow-up is required to verify results and a prospective clinical trial is currently testing this new approach in chest and abdomen stereotactic body radiotherapy.
- Find related publications in this database (using NLM MeSH Indexing)
-
Dose-Response Relationship, Radiation - administration & dosage
-
Humans - administration & dosage
-
Neoplasms - complications, radiotherapy
-
Organ Sparing Treatments - administration & dosage
-
Organs at Risk - radiation effects
-
Radiation Dose Hypofractionation - administration & dosage
-
Radiation Injuries - etiology, prevention & control
-
Radiation Protection - methods
-
Radiosurgery - adverse effects, methods
-
Radiotherapy Planning, Computer-Assisted - methods
-
Reproducibility of Results - administration & dosage
-
Sensitivity and Specificity - administration & dosage
-
Treatment Outcome - administration & dosage
- Find related publications in this database (Keywords)
-
Stereotactic body radiation therapy
-
Intensity-modulated radiotherapy
-
Efficacy
-
Toxicity
-
Organs at risk