Husic, R; Finzel, S; Stradner, MH; Dreu, M; Hofmeister, A; Beham-Schmid, C; Graninger, WB; Fessler, J; Dejaco, C.
Ultrasound in osteoarthritis of the hand: a comparison to computed tomography and histology.
Rheumatology (Oxford). 2022; 61(SI):SI73-SI80 Doi: 10.1093/rheumatology/keab526
Web of Science PubMed FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Husic Rusmir
Stradner Martin Helmut
Co-Autor*innen der Med Uni Graz
Beham-Schmid Christine
Dejaco Christian
Dreu Manuel
Fessler Johannes
Graninger Winfried
Hofmeister Alexander
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
OBJECTIVE: To compare structural findings between US, micro-CT (µCT) and histology in people with OA of the hands. METHODS: We analysed DIP and PIP joints of 31 fingers from 15 dissecting-room cadavers with OA of the hands. The occurrence of bone erosions and osteophytes were recorded by US, µCT and histology at 16 regions for each joint and compared for each method. RESULTS: In total, US (n = 558, 56.2% of 992 examined regions) and µCT (n = 493, 49.7%) detected a higher frequency of osteophytes at PIP and DIP joints than histology (n = 161, 23.4% of 689 histological examined regions; P = 0.01). We found a comparable number of erosions with each method [US, n = 52 (5.2%); µCT, n = 43 (4.3%); histology, n = 35 (5.2%)]. Both imaging techniques correlated moderately with each other regarding the detection of osteophytes (r = 0.54, P = 0.002) and erosions (r = 0.43, P = 0.017). Neither US nor µCT correlated with histology regarding erosions or osteophytes. With histology as the reference, US had a sensitivity of 80% and a specificity of 32% to detect osteophytes, whereas µCT had a sensitivity of 73% and a specificity of 27%. For erosions, sensitivities (US 10% and µCT 6%, respectively) were much lower. Microscopically, erosions contained fibrous myxoid tissue extending from subcortical cavities through the breach of cortical bone. CONCLUSIONS: The ability of US to identify osteophytes was comparable to that of µCT, yielding a good sensitivity when histology was used as the gold standard. The sensitivity of US and µCT to detecting erosions was low compared with histology.
Find related publications in this database (using NLM MeSH Indexing)
Hand - pathology
Humans - administration & dosage
Osteoarthritis - diagnostic imaging, pathology
Osteophyte - diagnostic imaging, pathology
Tomography, X-Ray Computed - administration & dosage
Ultrasonography - methods

Find related publications in this database (Keywords)
ultrasonography
osteoarthritis of the hands
bone erosions
micro-computed tomography