Gewählte Publikation:
SHR
Neuro
Krebs
Kardio
Lipid
Stoffw
Microb
Christiansen, SN; Filippou, G; Scire, CA; Balint, PV; Bruyn, GAW; Dalbeth, N; Dejaco, C; Delle Sedie, A; Filippucci, E; Hammer, HB; Iagnocco, A; Keen, HI; Kissin, EY; Koski, J; Mandl, P; Martin, J; De Miguel, E; Moller, I; Naredo, E; Pineda, C; Schmidt, WA; Stewart, S; D'Agostino, MA; Terslev, L.
Consensus-based semi-quantitative ultrasound scoring system for gout lesions: Results of an OMERACT Delphi process and web-reliability exercise
SEMIN ARTHRITIS RHEU. 2021; 51(3): 644-649.
Doi: 10.1016/j.semarthrit.2020.11.011
Web of Science
PubMed
FullText
FullText_MUG
- Co-Autor*innen der Med Uni Graz
-
Dejaco Christian
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- Objective: This study aimed to develop (1) a new ultrasound definition for aggregates and (2) a semi-quantitative ultrasound scoring system (0-3) for tophus, double contour and aggregates. Furthermore, the intraand inter-reader reliabilities of both the re-defined aggregates and the semi-quantitative scoring system were assessed using static image exercises. Methods: Thirty-seven rheumatologists were invited. A Delphi process was used for re-defining aggregates and for selecting a semi-quantitative scoring system with >75% agreement obligate for reaching consensus. Subsequently, a web-based exercise on static ultrasound images was conducted in order to assess the reliability of both the re-defined aggregates and the semi-quantitative scoring system. Results: Twenty rheumatologists contributed to all rounds of the Delphi and image exercises. A consensual re-definition of aggregates was obtained after three Delphi rounds but needed an overarching principle for scoring aggregates in patients. A consensus-based semi-quantitative ultrasound scoring system for gout lesions was developed after two Delphi rounds. The re-definition of aggregates showed good intra- and inter-reader reliability (k-values 0.71 and 0.61). The reliabilities of the scoring system were good for all lesions with slightly higher intra-reader (k-values 0.74-0.80) than inter-reader reliabilities (k-values 0.61-0.67). Conclusion: A re-definition of aggregates was obtained with a good reliability when assessing static images. The first consensus-based semi-quantitative ultrasound scoring system for gout-specific lesions was devel-oped with good inter-and intra-reader reliability for all lesions when tested in static images. The next step is to assess the reliabilities when scoring lesions in patients. (c) 2021 Elsevier Inc. All rights reserved.
- Find related publications in this database (Keywords)
-
Ultrasound
-
Gout
-
OMERACT
-
Scoring system
-
Delphi exercise
-
Reliability
-
Outcome measure