Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Christiansen, SN; Filippou, G; Scire, CA; Balint, PV; Bruyn, GAW; Dalbeth, N; Dejaco, C; Delle Sedie, A; Filippucci, E; Hammer, HB; Iagnocco, A; Keen, HI; Kissin, EY; Koski, J; Mandl, P; Martin, J; De Miguel, E; Moller, I; Naredo, E; Pineda, C; Schmidt, WA; Stewart, S; D'Agostino, MA; Terslev, L.
Consensus-based semi-quantitative ultrasound scoring system for gout lesions: Results of an OMERACT Delphi process and web-reliability exercise
SEMIN ARTHRITIS RHEU. 2021; 51(3): 644-649. Doi: 10.1016/j.semarthrit.2020.11.011
Web of Science PubMed FullText FullText_MUG

 

Co-Autor*innen der Med Uni Graz
Dejaco Christian
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Objective: This study aimed to develop (1) a new ultrasound definition for aggregates and (2) a semi-quantitative ultrasound scoring system (0-3) for tophus, double contour and aggregates. Furthermore, the intraand inter-reader reliabilities of both the re-defined aggregates and the semi-quantitative scoring system were assessed using static image exercises. Methods: Thirty-seven rheumatologists were invited. A Delphi process was used for re-defining aggregates and for selecting a semi-quantitative scoring system with >75% agreement obligate for reaching consensus. Subsequently, a web-based exercise on static ultrasound images was conducted in order to assess the reliability of both the re-defined aggregates and the semi-quantitative scoring system. Results: Twenty rheumatologists contributed to all rounds of the Delphi and image exercises. A consensual re-definition of aggregates was obtained after three Delphi rounds but needed an overarching principle for scoring aggregates in patients. A consensus-based semi-quantitative ultrasound scoring system for gout lesions was developed after two Delphi rounds. The re-definition of aggregates showed good intra- and inter-reader reliability (k-values 0.71 and 0.61). The reliabilities of the scoring system were good for all lesions with slightly higher intra-reader (k-values 0.74-0.80) than inter-reader reliabilities (k-values 0.61-0.67). Conclusion: A re-definition of aggregates was obtained with a good reliability when assessing static images. The first consensus-based semi-quantitative ultrasound scoring system for gout-specific lesions was devel-oped with good inter-and intra-reader reliability for all lesions when tested in static images. The next step is to assess the reliabilities when scoring lesions in patients. (c) 2021 Elsevier Inc. All rights reserved.

Find related publications in this database (Keywords)
Ultrasound
Gout
OMERACT
Scoring system
Delphi exercise
Reliability
Outcome measure
© Med Uni Graz Impressum