Tomin, T; Bordag, N; Zügner, E; Al-Baghdadi, A; Schinagl, M; Birner-Gruenberger, R; Schittmayer, M.
Blood Plasma Quality Control by Plasma Glutathione Status.
Antioxidants (Basel). 2021; 10(6): Doi: 10.3390/antiox10060864 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Birner-Grünberger Ruth
Bordag Natalie
Schittmayer-Schantl Matthias
Tomin Tamara
Co-Autor*innen der Med Uni Graz
Al-Baghdadi Abdullah
Schinagl Maximilian
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Timely centrifugation of blood for plasma preparation is a key step to ensure high plasma quality for analytics. Delays during preparation can significantly influence readouts of key clinical parameters. However, in a routine clinical environment, a strictly controlled timeline is often not feasible. The next best approach is to control for sample preparation delays by a marker that provides a readout of the time-dependent degradation of the sample. In this study, we explored the usefulness of glutathione status as potential marker of plasma preparation delay. As the concentration of glutathione in erythrocytes is at least two orders of magnitude higher than in plasma, even the slightest leakage of glutathione from the cells can be readily observed. Over the 3 h observation period employed in this study, we observed a linear increase of plasma concentrations of both reduced (GSH) and oxidized glutathione (GSSG). Artificial oxidation of GSH is prevented by rapid alkylation with N-ethylmaleimide directly in the blood sampling vessel as recently published. The observed relative leakage of GSH was significantly higher than that of GSSG. A direct comparison with plasma lactate dehydrogenase activity, a widely employed hemolysis marker, clearly demonstrated the superiority of our approach for quality control. Moreover, we show that the addition of the thiol alkylating reagent NEM directly to the blood tubes does not influence downstream analysis of other clinical parameters. In conclusion, we report that GSH gives an excellent readout of the duration of plasma preparation and the associated pre-analytical errors.

Find related publications in this database (Keywords)
glutathione
blood plasma
pre-analytical error
quality control
redox status
clinical chemistry
© Med Uni Graz Impressum